Import CBB refresh verify r4 stability baseline

Preserve tested Verify source, authoritative READY checks, bounded bridge retries, diagnostics and failure-only reporting. Include 336-test suite and packaging assets; exclude live Mentor samples, field logs, backups and distributions.
This commit is contained in:
阿白叔 committed 2026-09-29 15:05:20 +08:00
commit 11a2b2e46e
130 files changed
+19267

No files matched your search

Binary file not shown.

After

Width:  |  Height:  |  Size: 264 KiB

Binary file not shown.

After

Width:  |  Height:  |  Size: 4.8 KiB

@@ -0,0 +1,7 @@
<svg xmlns="http://www.w3.org/2000/svg" width="64" height="64" viewBox="0 0 64 64">
<rect x="3" y="3" width="58" height="58" rx="10" fill="#0f766e"/>
<rect x="11" y="12" width="42" height="32" rx="4" fill="#f8fafc"/>
<rect x="15" y="16" width="34" height="24" rx="2" fill="#dbeafe"/>
<path d="M20 29l6 6 14-14" fill="none" stroke="#16a34a" stroke-width="4" stroke-linecap="round" stroke-linejoin="round"/>
<rect x="25" y="47" width="14" height="4" rx="2" fill="#f8fafc"/>
</svg>

After

Width:  |  Height:  |  Size: 489 B

@@ -0,0 +1,128 @@
{
"schema_version": 1,
"rules": [
{
"rule_id": "license-selector",
"priority": 100,
"category": "SAFE_RECOVERY",
"phases": ["PCB_STARTING", "LICENSE_ACQUISITION", "DOCUMENT_ATTACH"],
"semantic_all": ["select the desired product license"],
"required_control_classes": ["GXWND", "Button"],
"action": "accept_license",
"channels": ["interface", "uia_select", "win32_button_click", "win32_mouse_click", "uia_invoke"],
"postcondition": "window_gone"
},
{
"rule_id": "database-restoration",
"priority": 95,
"category": "SAFE_RECOVERY",
"phases": ["PCB_STARTING", "DATABASE_RECOVERY", "DOCUMENT_ATTACH"],
"semantic_any": ["database restoration", "last user saved database", "数据库恢复"],
"action": "restore_last_saved",
"channels": ["uia_select", "win32_button_click", "uia_invoke"],
"postcondition": "window_gone"
},
{
"rule_id": "open-lock-confirm",
"priority": 90,
"category": "SAFE_RECOVERY",
"phases": ["PCB_STARTING", "DOCUMENT_ATTACH"],
"semantic_any": ["continue to open the design with read/write access permission", "confirm that no other users have the design open"],
"action": "confirm_open_lock",
"channels": ["win32_button_click", "uia_invoke"],
"postcondition": "window_gone"
},
{
"rule_id": "forward-annotation-confirm",
"priority": 85,
"category": "SAFE_CONFIRM",
"phases": ["PCB_STARTING", "DOCUMENT_ATTACH", "PROJECT_INTEGRATION"],
"semantic_all": ["new changes are ready for forward annotation", "do you want to forward annotate now"],
"action": "confirm_forward_annotation",
"channels": ["win32_button_click", "uia_invoke"],
"postcondition": "window_gone"
},
{
"rule_id": "reusable-block-save",
"priority": 90,
"category": "SAFE_CONFIRM",
"phases": ["SAVE", "CLOSE"],
"semantic_all": ["do you want to save the reusable block cell"],
"action": "save_reusable_block",
"channels": ["win32_button_click", "uia_invoke"],
"postcondition": "window_gone"
},
{
"rule_id": "integration-progress",
"priority": 80,
"category": "OBSERVE_PROGRESS",
"phases": ["PROJECT_INTEGRATION"],
"semantic_all": ["your task is being processed", "elapsed time"],
"semantic_none": ["error", "failed"],
"postcondition": "signature_changed"
},
{
"rule_id": "project-integration-panel",
"priority": 110,
"category": "OBSERVE_PROGRESS",
"phases": ["PROJECT_INTEGRATION"],
"semantic_all": ["project file and design", "forward annotation required"],
"semantic_none": ["there were errors", "error saving the reusable block"],
"postcondition": "signature_changed"
},
{
"rule_id": "integration-error",
"priority": 120,
"category": "FATAL_ACK",
"phases": ["PROJECT_INTEGRATION"],
"semantic_all": ["there were errors"],
"action": "acknowledge_fatal",
"channels": ["win32_button_click", "uia_invoke"],
"postcondition": "window_gone",
"error_code": "PROJECT_INTEGRATION_FAILED"
},
{
"rule_id": "save-error",
"priority": 120,
"category": "FATAL_ACK",
"phases": ["SAVE", "CLOSE"],
"semantic_all": ["error saving the reusable block"],
"action": "acknowledge_fatal",
"channels": ["win32_button_click", "uia_invoke"],
"postcondition": "window_gone",
"error_code": "SAVE_REUSABLE_BLOCK_FAILED"
},
{
"rule_id": "design-server-error",
"priority": 120,
"category": "FATAL_ACK",
"phases": ["PCB_STARTING", "DOCUMENT_ATTACH"],
"semantic_any": ["could not run server", "could not bring it alive"],
"action": "acknowledge_fatal",
"channels": ["win32_button_click", "uia_invoke"],
"postcondition": "window_gone",
"error_code": "DESIGN_SERVER_FAILED"
},
{
"rule_id": "database-load-error",
"priority": 120,
"category": "FATAL_ACK",
"phases": ["PCB_STARTING", "DATABASE_RECOVERY", "DOCUMENT_ATTACH"],
"semantic_all": ["database load is being terminated"],
"action": "acknowledge_fatal",
"channels": ["win32_button_click", "uia_invoke"],
"postcondition": "window_gone",
"error_code": "DATABASE_LOAD_FAILED"
},
{
"rule_id": "tip-of-day",
"priority": 50,
"category": "SAFE_CONFIRM",
"phases": ["PCB_STARTING", "DOCUMENT_ATTACH"],
"semantic_all": ["tip of the day"],
"action": "dismiss_tip",
"channels": ["win32_button_click", "uia_invoke"],
"postcondition": "window_gone"
}
]
}