fix: prove prewrite cancellation and bound recovery metadata lifetime
This commit is contained in:
1 parent
32dcd80d1e
commit
906cfc06be
14 files changed
+659
-60
No files matched your search
@@ -62,6 +62,51 @@ def _tip_target(snapshot):
|
||||
return target if target is not None and target.class_name == 'Button' else None
|
||||
|
||||
|
||||
def cancelled_prewrite_startup(job, pcb_pid=None):
|
||||
"""Positive ordinary pre-document cancellation proof; absence of Save is insufficient."""
|
||||
from .session_record import IDENTITY_KEYS, read_session_record
|
||||
try:
|
||||
if (job.get('diagnostic_only') is not False or job.get('interactive_input')
|
||||
or job.get('native_lm_verify') or job.get('post_repair_consent')
|
||||
or job.get('operation') != 'verify' or not job.get('operation_id')
|
||||
or not job.get('desktop', '').startswith('CbbVerify_')):
|
||||
return None
|
||||
root=Path(job['root'])
|
||||
if not Path(job['cancel_signal']).is_file() or (root/'save.log').exists():return None
|
||||
path=root/'events.jsonl'
|
||||
if path.stat().st_size>1024*1024:return None
|
||||
events=[json.loads(line) for line in path.read_text(encoding='utf-8').splitlines()]
|
||||
if any(str(e.get('stage','')).startswith(('save','integration','validate','failure_close'))
|
||||
or e.get('stage') in ('startup_write_admitted','startup_supervisor_write_possible','identity_verified')
|
||||
for e in events):return None
|
||||
stages=('startup_supervisor_no_write','startup_prewrite_ready','startup_cancelled_prewrite')
|
||||
selected=[]
|
||||
for stage in stages:
|
||||
matches=[(i,e) for i,e in enumerate(events) if e.get('stage')==stage]
|
||||
if len(matches)!=1:return None
|
||||
selected.append(matches[0])
|
||||
if [i for i,_ in selected]!=sorted(i for i,_ in selected):return None
|
||||
binding={k:job[k] for k in ('operation_id','project','pcb','desktop')}
|
||||
if any(any(e.get(k)!=v for k,v in binding.items()) for _,e in selected):return None
|
||||
ready,cancelled=selected[1][1],selected[2][1]
|
||||
pid=cancelled.get('pcb_pid')
|
||||
if (not pid or pcb_pid is not None and pid!=pcb_pid
|
||||
or cancelled.get('identity_verified') is not False or cancelled.get('write_admitted') is not False):return None
|
||||
if not any(e.get('stage')=='pcb_worker_started' and e.get('pcb_pid')==pid
|
||||
for e in events[selected[1][0]+1:selected[2][0]]):return None
|
||||
session=read_session_record(Path(job['session_record_path']),evidence_root=root)
|
||||
workers=[p for p in session.get('processes',()) if p.get('role')=='worker']
|
||||
if (session.get('operation_id')!=job['operation_id'] or session.get('desktop')!=job['desktop']
|
||||
or session.get('library')!=job['library'] or len(workers)!=1
|
||||
or not set(IDENTITY_KEYS)<=ready.get('worker_identity',{}).keys()
|
||||
or any(ready.get('worker_identity',{}).get(k)!=workers[0].get(k) for k in IDENTITY_KEYS)):return None
|
||||
baseline=ready.get('baseline')
|
||||
if not isinstance(baseline,dict) or not {'started_ns','files'}<=baseline.keys():return None
|
||||
return baseline
|
||||
except (OSError,ValueError,KeyError,TypeError):
|
||||
return None
|
||||
|
||||
|
||||
def close_failed_startup(job, pcb_pid, *, baseline_pids=(), emit=lambda **event: None,
|
||||
timeout_seconds=None, launcher_process=None):
|
||||
"""Normally close our empty PCB after a diagnosed database startup failure.
|
||||
@@ -95,10 +140,12 @@ def close_failed_startup(job, pcb_pid, *, baseline_pids=(), emit=lambda **event:
|
||||
and isinstance(job.get('diagnostic_log_baseline'), dict)
|
||||
and {'started_ns', 'files'} <= job['diagnostic_log_baseline'].keys()
|
||||
and not (root/'save.log').exists())
|
||||
ordinary_baseline=cancelled_prewrite_startup(job,pcb_pid)
|
||||
cancelled_prewrite=ordinary_baseline is not None
|
||||
# Diagnostic close already owns a 30-second cleanup budget. Start it
|
||||
# once here; the empty-to-loaded transition never resets that deadline.
|
||||
if timeout_seconds is None:
|
||||
timeout_seconds = 30 if cancelled_diagnostic else 20
|
||||
timeout_seconds = 30 if cancelled_diagnostic or cancelled_prewrite else 20
|
||||
deadline = time.monotonic() + max(0, timeout_seconds)
|
||||
sent = False
|
||||
declined_hwnd = None
|
||||
@@ -111,6 +158,7 @@ def close_failed_startup(job, pcb_pid, *, baseline_pids=(), emit=lambda **event:
|
||||
diagnostic_state = {'clicked': set()}
|
||||
def cleanup_post(hwnd, message):
|
||||
if (time.monotonic() >= deadline or _current_desktop_name() != desktop
|
||||
or cancelled_prewrite and cancelled_prewrite_startup(job,pcb_pid)!=ordinary_baseline
|
||||
or win32event.WaitForSingleObject(close_handle, 0) != win32con.WAIT_TIMEOUT
|
||||
or residual_sessions._handle_identity(close_handle) != close_identity
|
||||
or win32process.GetWindowThreadProcessId(hwnd)[1] != pcb_pid):
|
||||
@@ -150,19 +198,31 @@ def close_failed_startup(job, pcb_pid, *, baseline_pids=(), emit=lambda **event:
|
||||
or '-reusablecircuit' not in [a.casefold() for a in args]
|
||||
or expected not in [os.path.normcase(os.path.abspath(a)) for a in args[1:]]):
|
||||
raise ValueError('STARTUP_PROCESS_UNCONFIRMED')
|
||||
if cancelled_diagnostic and time.monotonic() < deadline:
|
||||
if cancelled_diagnostic or cancelled_prewrite:
|
||||
if time.monotonic() >= deadline:
|
||||
result['detail']='STARTUP_CLEANUP_TIMEOUT: original cleanup deadline reached'
|
||||
break
|
||||
if cancelled_prewrite and cancelled_prewrite_startup(job,pcb_pid)!=ordinary_baseline:
|
||||
raise ValueError('STARTUP_IDENTITY_UNCONFIRMED: pre-write phase proof changed')
|
||||
if (cancelled_diagnostic or cancelled_prewrite) and time.monotonic() < deadline:
|
||||
if close_handle is None:
|
||||
close_handle = handles.enter_context(residual_sessions._process_handle(pcb_pid))
|
||||
close_identity = residual_sessions._handle_identity(close_handle)
|
||||
if Path(close_identity['image']).name.casefold() != 'expeditionpcb.exe':
|
||||
raise ValueError('STARTUP_PROCESS_UNCONFIRMED')
|
||||
from .diagnostic_open import cancelled_startup_step
|
||||
def ordinary_identity():
|
||||
from .diagnostic_open import _load_evidence
|
||||
return (cancelled_prewrite_startup(job,pcb_pid)==ordinary_baseline
|
||||
and _load_evidence(job,pcb_pid,ordinary_baseline,require_autosave=False) is not None)
|
||||
closed, acted = cancelled_startup_step(job, pcb_pid, diagnostic_state,
|
||||
closed_frame=close_frame, deadline=deadline, post=cleanup_post, emit=emit)
|
||||
closed_frame=close_frame, deadline=deadline, post=cleanup_post, emit=emit,
|
||||
identity_check=ordinary_identity if cancelled_prewrite else None)
|
||||
if closed is not None and not sent:
|
||||
sent, close_frame = True, closed
|
||||
emit(stage='startup_close_requested', pcb_pid=pcb_pid, hwnd=closed,
|
||||
document_identity='native_path_pid_logs', cleanup='cancelled_diagnostic')
|
||||
document_identity='native_path_pid_logs',
|
||||
cleanup='cancelled_prewrite' if cancelled_prewrite else 'cancelled_diagnostic')
|
||||
if acted:
|
||||
continue
|
||||
if not sent:
|
||||
@@ -187,7 +247,10 @@ def close_failed_startup(job, pcb_pid, *, baseline_pids=(), emit=lambda **event:
|
||||
current = _startup_snapshot(hwnd, pcb_pid)
|
||||
if current != snapshot or _tip_target(current) != target:
|
||||
raise ValueError('STARTUP_TIP_CHANGED')
|
||||
win32gui.PostMessage(target.handle, win32con.BM_CLICK, 0, 0)
|
||||
if cancelled_diagnostic or cancelled_prewrite:
|
||||
cleanup_post(target.handle,win32con.BM_CLICK)
|
||||
else:
|
||||
win32gui.PostMessage(target.handle, win32con.BM_CLICK, 0, 0)
|
||||
dismissed_tips.add(hwnd)
|
||||
dismissed = True
|
||||
emit(stage='startup_tip_dismissed', pcb_pid=pcb_pid, hwnd=hwnd)
|
||||
@@ -207,7 +270,10 @@ def close_failed_startup(job, pcb_pid, *, baseline_pids=(), emit=lambda **event:
|
||||
if _cancel_target(current) != target or current != snapshot:
|
||||
raise ValueError('STARTUP_CANCEL_PROMPT_CHANGED')
|
||||
declined_kind, cancel = target
|
||||
win32gui.PostMessage(cancel.handle, win32con.BM_CLICK, 0, 0)
|
||||
if cancelled_diagnostic or cancelled_prewrite:
|
||||
cleanup_post(cancel.handle,win32con.BM_CLICK)
|
||||
else:
|
||||
win32gui.PostMessage(cancel.handle, win32con.BM_CLICK, 0, 0)
|
||||
declined_hwnd = hwnd
|
||||
emit(stage='startup_open_declined', pcb_pid=pcb_pid, hwnd=hwnd,
|
||||
control_id=cancel.control_id, prompt=declined_kind)
|
||||
@@ -251,7 +317,10 @@ def close_failed_startup(job, pcb_pid, *, baseline_pids=(), emit=lambda **event:
|
||||
close_identity = residual_sessions._handle_identity(close_handle)
|
||||
if Path(close_identity['image']).name.casefold() != 'expeditionpcb.exe':
|
||||
raise ValueError('STARTUP_PROCESS_UNCONFIRMED')
|
||||
win32gui.PostMessage(main[0], win32con.WM_CLOSE, 0, 0)
|
||||
if cancelled_diagnostic or cancelled_prewrite:
|
||||
cleanup_post(main[0],win32con.WM_CLOSE)
|
||||
else:
|
||||
win32gui.PostMessage(main[0], win32con.WM_CLOSE, 0, 0)
|
||||
close_frame = main[0]
|
||||
sent = True
|
||||
emit(stage='startup_close_requested', pcb_pid=pcb_pid, hwnd=main[0])
|
||||
|
||||
Reference in new issue
Block a user