feat: integrate native diagnostics and coordinated CBB transactions
This commit is contained in:
1 parent
9e230e1a46
commit
da67de026f
91 files changed
+14370
-435
No files matched your search
@@ -0,0 +1,338 @@
|
||||
import importlib
|
||||
import importlib.util
|
||||
from pathlib import Path
|
||||
|
||||
import pytest
|
||||
|
||||
|
||||
@pytest.fixture
|
||||
def diagnostic():
|
||||
assert importlib.util.find_spec('cbb_refresh_verify.diagnostic_open') is not None, 'diagnostic open module is missing'
|
||||
return importlib.import_module('cbb_refresh_verify.diagnostic_open')
|
||||
|
||||
|
||||
@pytest.fixture
|
||||
def job(tmp_path):
|
||||
project = tmp_path / 'IP101GR'
|
||||
pcb = project / 'PCB/IP101GR.pcb'
|
||||
pcb.parent.mkdir(parents=True)
|
||||
pcb.write_bytes(b'pcb')
|
||||
return {'project': str(project / 'IP101GR.prj'), 'pcb': str(pcb), 'root': str(tmp_path / 'evidence'),
|
||||
'desktop': 'CbbDiagnosticTest', 'timeout': .03}
|
||||
|
||||
|
||||
def write_logs(job, *, pid=42, foreign=False, success=True):
|
||||
project = Path(job['project']).parent
|
||||
logdir = Path(job['pcb']).parent / 'LogFiles'
|
||||
logdir.mkdir(parents=True, exist_ok=True)
|
||||
pcb = str(Path(job['pcb'])) if not foreign else str(project.parent / 'other/PCB/IP101GR.pcb')
|
||||
(logdir / 'PCBAutoSave.txt').write_text('Job Name: ' + pcb + '\n', encoding='utf-8')
|
||||
(logdir / 'PCBLogFile.txt').write_text('Successfully read the design.\n' if success else 'Loading\n', encoding='utf-8')
|
||||
database = str(project / 'database') if not foreign else str(project.parent / 'other/database')
|
||||
logs = project / 'database/cdbsvr/log/current'
|
||||
logs.mkdir(parents=True, exist_ok=True)
|
||||
(logs / 'current.txt').write_text(
|
||||
f'S: Project path [{database}] on file system [NTFS]\n'
|
||||
f'S: Project file (.prj) path [{project / "IP101GR.prj"}] on file system [NTFS]\n'
|
||||
f'S: Started up automatically by iCDB Client: ABS:ABS:{pid}\n'
|
||||
'S: iCDB database loaded\n'
|
||||
f'SC[455]: Registered sub-client [Expedition PCB_123] with ID [1] for session ID [455] host [Abs] user [ABS] process ID [{pid}]\n',
|
||||
encoding='utf-8')
|
||||
|
||||
|
||||
def test_old_success_logs_are_not_current_open_evidence(diagnostic, job):
|
||||
write_logs(job)
|
||||
baseline = diagnostic.snapshot_diagnostic_logs(job)
|
||||
assert diagnostic._load_evidence(job, 42, baseline) is None
|
||||
|
||||
|
||||
@pytest.mark.parametrize('pid,foreign,success', [(99, False, True), (42, True, True), (42, False, False)])
|
||||
def test_foreign_pid_path_or_incomplete_load_cannot_pass(diagnostic, job, pid, foreign, success):
|
||||
baseline = diagnostic.snapshot_diagnostic_logs(job)
|
||||
write_logs(job, pid=pid, foreign=foreign, success=success)
|
||||
assert diagnostic._load_evidence(job, 42, baseline) is None
|
||||
|
||||
|
||||
def test_current_full_path_and_pcb_pid_logs_prove_open_only(diagnostic, job):
|
||||
baseline = diagnostic.snapshot_diagnostic_logs(job)
|
||||
write_logs(job)
|
||||
evidence = diagnostic._load_evidence(job, 42, baseline)
|
||||
assert evidence['pcb'] == job['pcb']
|
||||
assert evidence['pcb_pid'] == 42
|
||||
|
||||
|
||||
def test_old_prefix_in_appended_log_cannot_supply_target_identity(diagnostic, job):
|
||||
write_logs(job)
|
||||
baseline = diagnostic.snapshot_diagnostic_logs(job)
|
||||
for path in Path(job['project']).parent.rglob('*.txt'):
|
||||
with path.open('a', encoding='utf-8') as output:
|
||||
output.write('unrelated new record\n')
|
||||
assert diagnostic._load_evidence(job, 42, baseline) is None
|
||||
|
||||
|
||||
def frame(job, *, title='IP101GR'):
|
||||
return {'hwnd': 10, 'pid': 42, 'class': 'Afx:123',
|
||||
'text': f'Expedition PCB - Reusable Block - [{title}]', 'enabled': True,
|
||||
'children': [{'hwnd': 11, 'class': 'MDIClient', 'text': '', 'parent': 10},
|
||||
{'hwnd': 12, 'class': 'Afx:document', 'text': title, 'parent': 11}]}
|
||||
|
||||
|
||||
def test_target_title_without_target_mdi_does_not_pass(diagnostic, job):
|
||||
window = frame(job)
|
||||
window['children'][1]['text'] = 'another_project'
|
||||
assert diagnostic._target_frame([window], Path(job['pcb']).stem) is None
|
||||
|
||||
|
||||
class Session:
|
||||
instances = []
|
||||
def __init__(self, job, pid, launcher):
|
||||
self.alive = True
|
||||
self.closed = False
|
||||
self.posted = []
|
||||
self.instances.append(self)
|
||||
def pcb_alive(self):
|
||||
return self.alive
|
||||
def launcher_alive(self):
|
||||
return self.alive
|
||||
def post(self, hwnd, message):
|
||||
self.posted.append((hwnd, message))
|
||||
self.alive = False
|
||||
def close(self):
|
||||
self.closed = True
|
||||
|
||||
|
||||
def test_unknown_prompt_is_preserved_and_never_closed(diagnostic, job, monkeypatch):
|
||||
job['diagnostic_log_baseline'] = diagnostic.snapshot_diagnostic_logs(job)
|
||||
write_logs(job)
|
||||
monkeypatch.setattr(diagnostic, '_NativeSession', Session)
|
||||
monkeypatch.setattr(diagnostic, '_windows', lambda pid: [frame(job),
|
||||
{'hwnd': 20, 'pid': 42, 'class': '#32770', 'text': 'Unknown question', 'children': []}])
|
||||
with pytest.raises(RuntimeError, match='DIAGNOSTIC_CLOSE_UNCONFIRMED'):
|
||||
diagnostic.check_target_window(job, 42, emit=lambda **event: None, error_reader=lambda: None)
|
||||
assert Session.instances[-1].posted == []
|
||||
assert Session.instances[-1].closed
|
||||
|
||||
|
||||
def test_success_posts_one_exact_close_and_reports_only_open_check(diagnostic, job, monkeypatch):
|
||||
job['diagnostic_log_baseline'] = diagnostic.snapshot_diagnostic_logs(job)
|
||||
write_logs(job)
|
||||
monkeypatch.setattr(diagnostic, '_NativeSession', Session)
|
||||
monkeypatch.setattr(diagnostic, '_windows', lambda pid: [frame(job)] if Session.instances[-1].alive else [])
|
||||
outcome = diagnostic.check_target_window(job, 42, emit=lambda **event: None, error_reader=lambda: None)
|
||||
assert outcome['status'] == 'PASS'
|
||||
assert outcome['check'] == 'native_open_only'
|
||||
assert outcome['native_processes_exited'] is True
|
||||
assert outcome['library_ownership'] == 'NOT_ASSESSED'
|
||||
assert Session.instances[-1].posted == [(10, 0x10)]
|
||||
assert Session.instances[-1].closed
|
||||
|
||||
|
||||
def test_transient_startup_window_cannot_abort_before_target_is_loaded(diagnostic, job, monkeypatch):
|
||||
job['diagnostic_log_baseline'] = diagnostic.snapshot_diagnostic_logs(job)
|
||||
write_logs(job)
|
||||
monkeypatch.setattr(diagnostic, '_NativeSession', Session)
|
||||
calls = []
|
||||
def windows(pid):
|
||||
calls.append(True)
|
||||
if len(calls) == 1:
|
||||
return [{'hwnd': 20, 'pid': 42, 'class': 'VendorSplash', 'text': '', 'children': []}]
|
||||
return [frame(job)] if Session.instances[-1].alive else []
|
||||
monkeypatch.setattr(diagnostic, '_windows', windows)
|
||||
job['timeout'] = 1
|
||||
assert diagnostic.check_target_window(job, 42, emit=lambda **event: None, error_reader=lambda: None)['status'] == 'PASS'
|
||||
assert Session.instances[-1].posted == [(10, 0x10)]
|
||||
|
||||
|
||||
def test_native_caption_variant_uses_proven_target_mdi(diagnostic, job, monkeypatch):
|
||||
job['diagnostic_log_baseline'] = diagnostic.snapshot_diagnostic_logs(job)
|
||||
write_logs(job)
|
||||
monkeypatch.setattr(diagnostic, '_NativeSession', Session)
|
||||
target = frame(job)
|
||||
target['text'] = 'Expedition PCB - [IP101GR]'
|
||||
monkeypatch.setattr(diagnostic, '_windows', lambda pid: [target] if Session.instances[-1].alive else [])
|
||||
assert diagnostic.check_target_window(job, 42, emit=lambda **event: None, error_reader=lambda: None)['status'] == 'PASS'
|
||||
|
||||
|
||||
def test_cancel_does_not_wait_for_open_timeout(diagnostic, job, monkeypatch):
|
||||
job['diagnostic_log_baseline'] = diagnostic.snapshot_diagnostic_logs(job)
|
||||
cancel = Path(job['root']).parent / 'cancel'
|
||||
cancel.touch()
|
||||
job['cancel_signal'] = str(cancel)
|
||||
monkeypatch.setattr(diagnostic, '_NativeSession', Session)
|
||||
monkeypatch.setattr(diagnostic, '_windows', lambda pid: [])
|
||||
with pytest.raises(RuntimeError, match='VERIFY_CANCELLED'):
|
||||
diagnostic.check_target_window(job, 42, emit=lambda **event: None, error_reader=lambda: None)
|
||||
assert Session.instances[-1].posted == []
|
||||
assert Session.instances[-1].closed
|
||||
|
||||
|
||||
def test_cancel_after_close_request_still_waits_for_own_launcher_exit(diagnostic, job, monkeypatch):
|
||||
job['diagnostic_log_baseline'] = diagnostic.snapshot_diagnostic_logs(job)
|
||||
write_logs(job)
|
||||
cancel = Path(job['root']).parent / 'cancel'
|
||||
job['cancel_signal'] = str(cancel)
|
||||
class DelayedLauncher(Session):
|
||||
polls = 0
|
||||
def post(self, hwnd, message):
|
||||
super().post(hwnd, message)
|
||||
cancel.touch()
|
||||
def launcher_alive(self):
|
||||
self.polls += 1
|
||||
return self.polls < 3
|
||||
monkeypatch.setattr(diagnostic, '_NativeSession', DelayedLauncher)
|
||||
monkeypatch.setattr(diagnostic, '_windows', lambda pid: [frame(job)] if Session.instances[-1].alive else [])
|
||||
assert diagnostic.check_target_window(job, 42, emit=lambda **event: None, error_reader=lambda: None)['status'] == 'PASS'
|
||||
assert Session.instances[-1].polls >= 3
|
||||
|
||||
|
||||
@pytest.mark.parametrize('owner,window_class', [(10, 'VendorModal'), (0, 'VendorModal'),
|
||||
(0, 'Internet Explorer_Hidden')])
|
||||
def test_unknown_custom_owned_window_blocks_close(diagnostic, job, monkeypatch, owner, window_class):
|
||||
job['diagnostic_log_baseline'] = diagnostic.snapshot_diagnostic_logs(job)
|
||||
write_logs(job)
|
||||
monkeypatch.setattr(diagnostic, '_NativeSession', Session)
|
||||
monkeypatch.setattr(diagnostic, '_windows', lambda pid: [frame(job),
|
||||
{'hwnd': 20, 'pid': 42, 'class': window_class, 'text': 'Unclassified prompt',
|
||||
'owner': owner, 'enabled': True, 'children': []}])
|
||||
with pytest.raises(RuntimeError, match='DIAGNOSTIC_CLOSE_UNCONFIRMED'):
|
||||
diagnostic.check_target_window(job, 42, emit=lambda **event: None, error_reader=lambda: None)
|
||||
assert Session.instances[-1].posted == []
|
||||
|
||||
|
||||
def test_empty_desktop_resets_stale_win32_last_error(diagnostic, monkeypatch):
|
||||
import win32api
|
||||
import win32gui
|
||||
import pywintypes
|
||||
seen = []
|
||||
def empty(callback, context):
|
||||
seen.append(win32api.GetLastError())
|
||||
raise pywintypes.error(0, 'EnumWindows', 'empty desktop')
|
||||
monkeypatch.setattr(win32gui, 'EnumWindows', empty)
|
||||
win32api.SetLastError(170)
|
||||
assert diagnostic._windows(42) == []
|
||||
assert seen == [0]
|
||||
|
||||
|
||||
def test_missing_launcher_cannot_claim_verified_native_release(diagnostic, job):
|
||||
with pytest.raises(RuntimeError, match='DIAGNOSTIC_LAUNCHER_REQUIRED'):
|
||||
diagnostic._NativeSession(job, 42, None)
|
||||
|
||||
|
||||
def test_buffered_full_pcb_path_must_be_verified_after_normal_close(diagnostic, job, monkeypatch):
|
||||
job['diagnostic_log_baseline'] = diagnostic.snapshot_diagnostic_logs(job)
|
||||
write_logs(job)
|
||||
autosave = Path(job['pcb']).parent / 'LogFiles/PCBAutoSave.txt'
|
||||
autosave.write_text('', encoding='utf-8')
|
||||
class BufferedSession(Session):
|
||||
def post(self, hwnd, message):
|
||||
super().post(hwnd, message)
|
||||
autosave.write_text('Job Name: ' + job['pcb'] + '\n', encoding='utf-8')
|
||||
monkeypatch.setattr(diagnostic, '_NativeSession', BufferedSession)
|
||||
monkeypatch.setattr(diagnostic, '_windows', lambda pid: [frame(job)] if Session.instances[-1].alive else [])
|
||||
outcome = diagnostic.check_target_window(job, 42, emit=lambda **event: None, error_reader=lambda: None)
|
||||
assert outcome['status'] == 'PASS'
|
||||
assert Session.instances[-1].posted == [(10, 0x10)]
|
||||
|
||||
|
||||
def test_large_unrelated_history_does_not_block_current_evidence(diagnostic, job):
|
||||
logs = Path(job['project']).parent / 'database/cdbsvr/log'
|
||||
for index in range(270):
|
||||
directory = logs / f'2000-01-01 00.00.00-{index:05}'
|
||||
directory.mkdir(parents=True)
|
||||
(directory / '2000.01.01.txt').write_bytes(b'old unrelated history\n' * 14000)
|
||||
baseline = diagnostic.snapshot_diagnostic_logs(job)
|
||||
write_logs(job)
|
||||
assert diagnostic._load_evidence(job, 42, baseline) is not None
|
||||
|
||||
|
||||
def test_pcb_logs_follow_actual_pcb_directory(diagnostic, job):
|
||||
pcb = Path(job['pcb']).parent.parent / 'AlternativePCB/IP101GR.pcb'
|
||||
pcb.parent.mkdir()
|
||||
pcb.write_bytes(b'pcb')
|
||||
job['pcb'] = str(pcb)
|
||||
baseline = diagnostic.snapshot_diagnostic_logs(job)
|
||||
write_logs(job)
|
||||
assert diagnostic._load_evidence(job, 42, baseline)['pcb'] == str(pcb)
|
||||
|
||||
|
||||
def test_only_exact_owned_save_prompt_gets_no_after_diagnostic_close(diagnostic, job, monkeypatch):
|
||||
job['diagnostic_log_baseline'] = diagnostic.snapshot_diagnostic_logs(job)
|
||||
write_logs(job)
|
||||
class SaveSession(Session):
|
||||
closing = False
|
||||
def post(self, hwnd, message):
|
||||
self.posted.append((hwnd, message))
|
||||
if message == 0x10:
|
||||
self.closing = True
|
||||
else:
|
||||
self.alive = False
|
||||
closing_scans = []
|
||||
def windows(pid):
|
||||
state = Session.instances[-1]
|
||||
if not state.closing:
|
||||
return [frame(job)]
|
||||
closing_scans.append(True)
|
||||
if len(closing_scans) == 1:
|
||||
return [{'hwnd': 20, 'pid': 42, 'class': '#32770', 'text': '',
|
||||
'owner': 10, 'children': []}]
|
||||
return [{'hwnd': 20, 'pid': 42, 'class': '#32770', 'text': 'Expedition PCB',
|
||||
'owner': 10, 'children': [
|
||||
{'hwnd': 30, 'class': 'Static', 'text': 'Do you want to save the reusable block cell?', 'id': -1},
|
||||
{'hwnd': 31, 'class': 'Button', 'text': '&No', 'id': 7}]}]
|
||||
monkeypatch.setattr(diagnostic, '_NativeSession', SaveSession)
|
||||
monkeypatch.setattr(diagnostic, '_windows', windows)
|
||||
outcome = diagnostic.check_target_window(job, 42, emit=lambda **event: None, error_reader=lambda: None)
|
||||
assert outcome['status'] == 'PASS'
|
||||
assert Session.instances[-1].posted == [(10, 0x10), (31, 0xF5)]
|
||||
|
||||
|
||||
def test_no_pass_when_normal_close_never_flushes_full_pcb_path(diagnostic, job, monkeypatch):
|
||||
job['diagnostic_log_baseline'] = diagnostic.snapshot_diagnostic_logs(job)
|
||||
write_logs(job)
|
||||
(Path(job['pcb']).parent / 'LogFiles/PCBAutoSave.txt').write_bytes(b'')
|
||||
monkeypatch.setattr(diagnostic, '_NativeSession', Session)
|
||||
monkeypatch.setattr(diagnostic, '_windows', lambda pid: [frame(job)] if Session.instances[-1].alive else [])
|
||||
with pytest.raises(RuntimeError, match='fresh full PCB path not confirmed after close'):
|
||||
diagnostic.check_target_window(job, 42, emit=lambda **event: None, error_reader=lambda: None)
|
||||
assert Session.instances[-1].posted == [(10, 0x10)]
|
||||
|
||||
|
||||
@pytest.mark.parametrize('filename,accepted', [('IP101GR.pcb', True), ('Foreign.pcb', False)])
|
||||
def test_standard_save_question_requires_exact_target_filename(diagnostic, job, monkeypatch, filename, accepted):
|
||||
job['diagnostic_log_baseline'] = diagnostic.snapshot_diagnostic_logs(job)
|
||||
write_logs(job)
|
||||
class SaveSession(Session):
|
||||
closing = False
|
||||
def post(self, hwnd, message):
|
||||
self.posted.append((hwnd, message))
|
||||
if message == 0x10:
|
||||
self.closing = True
|
||||
else:
|
||||
self.alive = False
|
||||
def windows(pid):
|
||||
if not Session.instances[-1].closing:
|
||||
return [frame(job)]
|
||||
return [{'hwnd': 20, 'pid': 42, 'class': '#32770', 'text': 'Expedition PCB', 'owner': 10,
|
||||
'children': [{'hwnd': 30, 'class': 'Static', 'text': f'Save changes to {filename}?', 'id': -1},
|
||||
{'hwnd': 31, 'class': 'Button', 'text': '否(&N)', 'id': 7},
|
||||
{'hwnd': 32, 'class': 'Button', 'text': '是(&Y)', 'id': 6},
|
||||
{'hwnd': 33, 'class': 'Button', 'text': '取消', 'id': 2}]}]
|
||||
monkeypatch.setattr(diagnostic, '_NativeSession', SaveSession)
|
||||
monkeypatch.setattr(diagnostic, '_windows', windows)
|
||||
if accepted:
|
||||
assert diagnostic.check_target_window(job, 42, emit=lambda **event: None, error_reader=lambda: None)['status'] == 'PASS'
|
||||
assert Session.instances[-1].posted == [(10, 0x10), (31, 0xF5)]
|
||||
else:
|
||||
with pytest.raises(RuntimeError, match='DIAGNOSTIC_CLOSE_UNCONFIRMED'):
|
||||
diagnostic.check_target_window(job, 42, emit=lambda **event: None, error_reader=lambda: None)
|
||||
assert Session.instances[-1].posted == [(10, 0x10)]
|
||||
|
||||
|
||||
def test_recycled_window_from_another_pid_never_receives_close(diagnostic, monkeypatch):
|
||||
import win32process
|
||||
session = diagnostic._NativeSession.__new__(diagnostic._NativeSession)
|
||||
session.pid = 42
|
||||
session.pcb_alive = lambda: True
|
||||
monkeypatch.setattr(win32process, 'GetWindowThreadProcessId', lambda hwnd: (1, 99))
|
||||
with pytest.raises(RuntimeError, match='DIAGNOSTIC_STALE_WINDOW'):
|
||||
session.post(10, 0x10)
|
||||
Reference in new issue
Block a user