fix: close owned PCB startup failures before ICDB recovery
This commit is contained in:
1 parent
39985f7cfd
commit
ec78dd722c
5 files changed
+360
-1
No files matched your search
@@ -0,0 +1,80 @@
|
||||
# Issue #2: release the PCB launched by a failed database open
|
||||
|
||||
Branch: `codex/temp-issue-2-icdb-recovery`.
|
||||
|
||||
## Field failure
|
||||
|
||||
The issue attachment records an iCDB lost-server-session error while opening
|
||||
`1GPHY_8211`. The supervisor declined the database log viewer and cancelled the
|
||||
worker. Because document identity had not been established, the existing
|
||||
document-close helper was never called. PCB and its launcher remained alive;
|
||||
the subsequent Repair attempt returned `REPAIR_DATABASE_IN_USE` and the other
|
||||
380 queued entries were skipped. There is no evidence of native Repair actually
|
||||
running on that field database.
|
||||
|
||||
## Change
|
||||
|
||||
The worker now has a separate startup-failure close path. It requires a current
|
||||
iCDB diagnosis or a database-load-failure dialog belonging to this PCB during
|
||||
startup. It checks the private desktop, excludes pre-existing process IDs, and
|
||||
matches the complete PCB path and ReusableCircuit argument. Only an enabled
|
||||
empty PCB main window, without modal dialogs, MDI documents or database address
|
||||
records, receives a cooperative `WM_CLOSE`. A requested close is not treated as
|
||||
success until process exit is observed. Ambiguous or busy sessions are retained.
|
||||
|
||||
The supervisor allows up to 40 seconds for fatal-error cleanup so that the
|
||||
worker's 20-second startup-close window can complete before recovery begins.
|
||||
The existing repair preconditions, backups and success checks remain in force.
|
||||
Each attempt writes `startup-close.json` and close-request/result events.
|
||||
|
||||
## Verification
|
||||
|
||||
Regression tests cover the missing pre-identity cleanup route, real observed
|
||||
empty-window titles, exact path matching, pre-existing processes, another
|
||||
desktop, live address records, modal and MDI windows, disabled windows, unrelated
|
||||
failure records and a close request that does not result in exit.
|
||||
Delayed dialog/address release and delayed process exit are also covered.
|
||||
Validation: `python -m pytest -q` — 491 passed, one existing pywinauto COM-mode
|
||||
warning; `python -m compileall -q src tests` and `git diff --check` passed.
|
||||
|
||||
A new isolated local library was created with the existing
|
||||
`tools/validate_icdb_open_repair_reopen.py` tool, output
|
||||
`diagnostics/issue2-startup-20261102`. No production library was changed.
|
||||
The test damages only the new copy's database header; it does not reproduce the
|
||||
field server-session-loss condition.
|
||||
|
||||
The real Mentor opening run produced `MENTOR_DATABASE_LOAD_FAILED`, then:
|
||||
|
||||
- `startup_close_requested` for the launched PCB PID 6532;
|
||||
- `startup_close_result: CLOSED`;
|
||||
- worker and supervisor both recorded `process_exit_confirmed`, with no
|
||||
remaining PCB processes.
|
||||
|
||||
The subsequent separate native Repair run was able to start and completed as
|
||||
`RESTORED_REVIEW_REQUIRED`, using the fixture's historical backup. This proves
|
||||
the failed-open session no longer blocks the next repair operation in this
|
||||
fixture. It does not prove automatic recovery of the field database or establish
|
||||
that an older backup contains the desired design revision.
|
||||
|
||||
The separate `open-after` run on the same restored fixture completed native
|
||||
integration, Save/IsSaved/Close/Quit, confirmed process release and returned
|
||||
`PASS`, `safe_to_continue=True`, `READY (IsVerifiedReuseBlock, raw=1)`.
|
||||
The `compare` phase passed all seven checks, including absence of the original
|
||||
opening error and unchanged source-fixture database SHA-256. Its
|
||||
`server_session_loss_reproduced` field is explicitly `false`.
|
||||
|
||||
Reproduction commands (set `PYTHONPATH=src`; setup requires a new output name):
|
||||
|
||||
```powershell
|
||||
python tools/validate_icdb_open_repair_reopen.py setup --output issue2-startup-20261102
|
||||
python tools/validate_icdb_open_repair_reopen.py open-before --output issue2-startup-20261102
|
||||
python tools/validate_icdb_open_repair_reopen.py repair --output issue2-startup-20261102
|
||||
python tools/validate_icdb_open_repair_reopen.py open-after --output issue2-startup-20261102
|
||||
python tools/validate_icdb_open_repair_reopen.py compare --output issue2-startup-20261102
|
||||
```
|
||||
|
||||
The stages are deliberately separate: the test fixture has a format-corruption
|
||||
error and historical-backup recovery, not the field lost-session auto-repair
|
||||
trigger. The test does not change production handling of old-backup recovery.
|
||||
|
||||
READY filtering, hash-scope changes and CBB CRUD are outside this focused fix.
|
||||