fix: retain unknown startup windows and expose native dispatch errors

This commit is contained in:
阿白叔 committed 2026-11-02 22:19:59 +08:00
1 parent 46c3e72364
commit ffa7e84d43
4 files changed
+154 -8

No files matched your search

+9 -2
View File
@@ -103,7 +103,14 @@ def close_failed_startup(job, pcb_pid, *, baseline_pids=(), emit=lambda **event:
and win32gui.GetWindowText(w).strip() in (
'Expedition PCB', 'Expedition PCB - Reusable Block')
and win32gui.IsWindowEnabled(w)]
dialogs = any(win32gui.GetClassName(w) == '#32770' for w in windows)
observed = [{'hwnd': w, 'class': win32gui.GetClassName(w),
'title': win32gui.GetWindowText(w), 'enabled': bool(win32gui.IsWindowEnabled(w))}
for w in windows]
benign = [w for w in observed if w['title'] == '' and w['class'] in (
'UAC_InputIndicatorOverlayWnd', 'UAC Input Indicator')]
unknown = [w for w in observed if w['hwnd'] not in main and w not in benign]
result.update(owned_windows=observed, unknown_windows=unknown,
benign_auxiliary_windows=benign)
documents = []
def child(hwnd, _):
if (win32gui.GetClassName(hwnd) == 'MDIClient'
@@ -112,7 +119,7 @@ def close_failed_startup(job, pcb_pid, *, baseline_pids=(), emit=lambda **event:
if len(main) == 1:
win32gui.EnumChildWindows(main[0], child, None)
addresses = unreleased_addresses(job['lmc_file'], job['project'], job['pcb'])
if len(main) == 1 and not dialogs and not documents and not addresses:
if len(main) == 1 and not unknown and not documents and not addresses:
win32gui.PostMessage(main[0], win32con.WM_CLOSE, 0, 0)
sent = True
emit(stage='startup_close_requested', pcb_pid=pcb_pid, hwnd=main[0])
+39 -6
View File
@@ -218,23 +218,48 @@ def _close_probe_dialogs(desktop, owned_pids):
return # Never close a parent with an unreleased child.
def _probe_add_dialog(app, job, desktop, owned_pids, root):
def _exception_details(error):
import traceback
return {'type': f'{type(error).__module__}.{type(error).__name__}', 'message': str(error),
'args': json.loads(json.dumps(error.args, default=str)),
'hresult': getattr(error, 'hresult', None),
'traceback': ''.join(traceback.format_exception(type(error), error, error.__traceback__))}
def _dispatch_diagnostics(root, stage, app, library, *, paths=None):
"""Read only three known DISPIDs, preserving errors hidden by dynamic COM."""
record = {'stage': stage, 'members': {}}
for label, obj, name in (('application.OnReusableBlocksEditor', app, 'OnReusableBlocksEditor'),
('application.Quit', app, 'Quit'), ('library.Close', library, 'Close')):
try:
record['members'][label] = {'dispid': obj._oleobj_.GetIDsOfNames(name)}
except Exception as error:
record['members'][label] = {'error': _exception_details(error)}
if paths is not None:
record['paths'] = paths
with (Path(root)/'dispatch-diagnostics.jsonl').open('a', encoding='utf-8') as stream:
stream.write(json.dumps(record, ensure_ascii=False, default=str) + '\n')
def _probe_add_dialog(app, job, desktop, owned_pids, root, *, library=None):
try:
return _probe_add_dialog_impl(app, job, desktop, owned_pids, root)
return _probe_add_dialog_impl(app, job, desktop, owned_pids, root, library=library)
finally:
import gc
gc.collect() # Release UIA wrappers before closing native child dialogs.
_close_probe_dialogs(desktop, owned_pids)
def _probe_add_dialog_impl(app, job, desktop, owned_pids, root):
def _probe_add_dialog_impl(app, job, desktop, owned_pids, root, *, library=None):
"""Diagnostic only: proven editor/UIA tab and resource1103 controls.
This function has no production capability override. It is called only
after this worker itself creates a new disposable library.
"""
import pythoncom, win32con, win32gui, win32process
_dispatch_diagnostics(root, 'before-pywinauto-import', app, library)
from pywinauto import Desktop
_dispatch_diagnostics(root, 'after-pywinauto-import', app, library)
from .backup_recovery import _align_library
from .management import source_project
source, pcb, top = source_project(job['source'], job.get('top_level_block', ''))
@@ -242,6 +267,8 @@ def _probe_add_dialog_impl(app, job, desktop, owned_pids, root):
if not source.is_relative_to(Path(root).parent.resolve()/source_folder):
raise ValueError('隔离新增只允许使用本次复制的来源工程。')
_align_library(source, pcb, Path(job['library']))
_dispatch_diagnostics(root, 'after-source-alignment', app, library,
paths={'source': str(source), 'pcb': str(pcb), 'library_argument': job['library']})
validate_name(job['name'])
deadline = time.monotonic() + float(job['timeout_seconds'])
def find_window(title):
@@ -545,7 +572,7 @@ def _catalog_com(job, root):
if library is None or Path(str(library.FullName)).resolve() != Path(job['library']).resolve():
raise RuntimeError('原生返回中心库身份不一致。')
if job['operation'] in ('probe_create_add', 'probe_readd'):
_probe_add_dialog(app, job, desktop, owned_pids, root)
_probe_add_dialog(app, job, desktop, owned_pids, root, library=library)
entries = []
parts = library.Partitions(7)
for i in range(1, int(parts.Count) + 1):
@@ -569,14 +596,19 @@ def _catalog_com(job, root):
result.update(success=True, library=str(library.FullName), flow=int(library.FlowType), entries=entries)
except Exception as error:
result['detail'] = str(error)
result['exception'] = _exception_details(error)
finally:
if library is not None:
try: library.Close()
except Exception as error: result['close_detail'] = str(error)
except Exception as error:
result['close_detail'] = str(error)
result['close_exception'] = _exception_details(error)
library = None
if app is not None:
try: app.Quit()
except Exception as error: result['quit_detail'] = str(error)
except Exception as error:
result['quit_detail'] = str(error)
result['quit_exception'] = _exception_details(error)
app = None
stop.set()
if watcher:
@@ -630,6 +662,7 @@ def management_worker_main(request_path):
raise ValueError('未验证的原生管理操作')
except Exception as error:
result['detail'] = str(error)
result['exception'] = _exception_details(error)
finally:
_write_json(root/'result.json', result)
return 0 if result['success'] and result['safe_to_continue'] else 2