"""Regression cases for the PCB/iCDB emergency shutdown defects. Native Mentor boundaries are replaced; no production library is opened. """ from pathlib import Path from types import SimpleNamespace import pytest from cbb_refresh_verify import mentor_adapter as adapter from cbb_refresh_verify.verify_runner import VerifyResult, run_batch from test_verify_worker_stability import exercise_worker from test_dialog_rules import prompt, ASSETS from cbb_refresh_verify.dialog_rules import decide, load_rules def test_network_timeout_cannot_remove_database_advertisement(tmp_path, monkeypatch): address = tmp_path / 'database/cdbsvr/sAddress.adr' address.parent.mkdir(parents=True) original = b'guid\n192.168.1.10\n10062\n1094\n' address.write_bytes(original) monkeypatch.setattr(adapter, 'probe_icdb_server', lambda *a: (False, 'timeout')) result = adapter.prepare_icdb_address(tmp_path / 'database', tmp_path / 'evidence') assert address.exists(), 'A timeout is not proof the database owner is dead' assert address.read_bytes() == original assert result['status'] == 'UNREACHABLE' @pytest.mark.parametrize('state', ['LIVE', 'UNREACHABLE', 'INVALID']) def test_address_probe_result_is_not_a_substitute_for_native_verify(tmp_path, monkeypatch, state): job, events, execute = exercise_worker(tmp_path, monkeypatch) monkeypatch.setattr(adapter, 'prepare_icdb_address', lambda *a, **k: {'status': state}) assert execute()['status'] == 'PASS' assert any(e['stage'] == 'pcb_launch' for e in events) @pytest.mark.parametrize('text', [ 'Continue to open the design with read/write access permission?', 'Confirm that no other users have the design open', 'Database restoration: last user saved database', ]) def test_database_recovery_requires_manual_review_without_click(text): decision = decide(prompt(text), load_rules(ASSETS / 'dialog_rules.v1.json')) assert decision.error_code == 'DATABASE_RECOVERY_REQUIRED' assert not decision.action def test_unsafe_result_stops_batch_even_when_reported_pass(): calls = [] def verify(item): calls.append(item) return VerifyResult('PASS', safe_to_continue=False) results = run_batch(['A', 'B'], verifier=verify) assert calls == ['A'] assert results[1].status == 'SKIPPED' def test_cleanup_does_not_force_terminate_native_database_owner(monkeypatch): killed = [] import win32api monkeypatch.setattr(adapter.subprocess, 'run', lambda *args, **kwargs: killed.append(args)) monkeypatch.setattr(win32api, 'TerminateProcess', lambda *args: killed.append(args)) monkeypatch.setattr(adapter, '_process_details', lambda name: [(22, 'ExpeditionPCB.exe', 'pcb', 11)] if name == 'ExpeditionPCB.exe' else []) events = [] result = adapter.cleanup_verify_processes(None, 22, 11, emit=lambda **e: events.append(e)) assert killed == [] assert result['safe_to_continue'] is False assert result['remaining_pids'] == [22] assert any(e['stage'] == 'process_retained' for e in events) def test_cleanup_enumeration_failure_cannot_confirm_release(monkeypatch): def fail(name): raise OSError('access denied') monkeypatch.setattr(adapter, '_process_details', fail) result = adapter.cleanup_verify_processes(None, 22) assert result['safe_to_continue'] is False def test_python_com_references_are_released_before_save_helper(tmp_path, monkeypatch): import weakref job, events, execute = exercise_worker(tmp_path, monkeypatch) references = [] class ComObject: pass def attach(*a, **k): objects = tuple(ComObject() for _ in range(3)) references.extend(weakref.ref(obj) for obj in objects) return objects monkeypatch.setattr('cbb_refresh_verify.pcb_bridge.wait_for_target_document', attach) original = adapter.subprocess.Popen def helper(*a, **k): assert all(ref() is None for ref in references), 'Python still owns PCB COM references' return original(*a, **k) monkeypatch.setattr(adapter.subprocess, 'Popen', helper) assert execute()['status'] == 'PASS' def test_desktop_abort_does_not_kill_native_process_tree(monkeypatch): from cbb_refresh_verify import desktop_worker as desktop worker = desktop.DesktopWorker.__new__(desktop.DesktopWorker) worker.job_bound = True worker.job = object() worker.handle = object() worker.pid = 101 worker.companions = [] terminated = [] job_kills = [] monkeypatch.setattr(desktop.win32job, 'TerminateJobObject', lambda *a: job_kills.append(a)) monkeypatch.setattr(desktop.win32process, 'TerminateProcess', lambda h, code: terminated.append(h)) monkeypatch.setattr(adapter, '_process_details', lambda name: []) worker.kill() assert job_kills == [], 'Terminating the job interrupts PCB and cdbsvr writes' assert worker.handle in terminated def test_saved_pcb_with_address_records_remains_an_execution_result_for_bridge_validation(tmp_path, monkeypatch): job, events, execute = exercise_worker(tmp_path, monkeypatch) original = adapter.subprocess.Popen def helper(*a, **k): address = Path(job['project']).parent / 'database/cdbsvr/sAddress.adr' address.parent.mkdir(parents=True) address.write_text('still owned', encoding='ascii') return original(*a, **k) monkeypatch.setattr(adapter.subprocess, 'Popen', helper) assert execute()['status'] == 'PASS' assert any(e['stage'] == 'icdb_address_remaining' for e in events) def test_retained_pcb_after_close_cannot_pass_or_be_killed(tmp_path, monkeypatch): from itertools import count job, events, execute = exercise_worker(tmp_path, monkeypatch) calls = count() monkeypatch.setattr(adapter, 'pcb_processes', lambda: () if next(calls) == 0 else ((2, 'ExpeditionPCB.exe', 'pcb'),)) clock = count(step=40) monkeypatch.setattr(adapter.time, 'monotonic', lambda: next(clock)) with pytest.raises(RuntimeError, match='PCB_RELEASE_UNCONFIRMED'): execute() assert not any(e['stage'] == 'complete' for e in events) def test_library_manager_close_does_not_force_kill_database_owner(): from cbb_refresh_verify.library_manager_verify import LibraryVerifySession killed = [] def wait(**kw): import subprocess raise subprocess.TimeoutExpired('LibraryManager', 5) process = SimpleNamespace(poll=lambda: None, wait=wait, terminate=lambda: killed.append('terminate'), kill=lambda: killed.append('kill')) session = LibraryVerifySession(SimpleNamespace(close=lambda: None), process, 1, Path('lib.lmc'), 'CBB') session.close() assert killed == [] def test_supervisor_rejects_pass_when_native_release_is_unconfirmed(tmp_path, monkeypatch): import json from test_verify_runner import fixture, request, PORTS_OK from cbb_refresh_verify.verify_runner import run_verify fixture(tmp_path) class Worker: desktop = None returncode = 0 def __init__(self, command, *_a, **_k): root = Path(command[-1]).parent (root / 'outcome.json').write_text('{"status":"PASS"}', encoding='utf-8') (root / 'backup/CBB').mkdir(parents=True) (root / 'backup/CBB/original.bin').write_bytes(b'original') def poll(self): return 0 def close(self): pass monkeypatch.setattr('cbb_refresh_verify.desktop_worker.DesktopWorker', Worker) monkeypatch.setattr('cbb_refresh_verify.verify_runner._cleanup_session_processes', lambda *a, **k: {'safe_to_continue': False, 'remaining_pids': [42]}) monkeypatch.setattr('cbb_refresh_verify.verify_diagnostics.capture_failure_logs_with_timeout', lambda *a: None) bridge_calls = [] result = run_verify(request(tmp_path), port_check=PORTS_OK, flag_reader=lambda *a: bridge_calls.append(a)) assert result.status == 'FAIL' assert not result.safe_to_continue assert bridge_calls == [] root = result.evidence_path.parent assert (root / 'backup/CBB/original.bin').read_bytes() == b'original' recovery = json.loads((root / 'recovery-required.json').read_text(encoding='utf-8')) assert recovery['release']['remaining_pids'] == [42] assert recovery['desktop'].startswith('CbbVerify_') def test_existing_pcb_session_blocks_before_mutating_project(tmp_path, monkeypatch): job, events, execute = exercise_worker(tmp_path, monkeypatch) monkeypatch.setattr(adapter, 'pcb_processes', lambda: ((20, 'ExpeditionPCB.exe', f'ExpeditionPCB.exe "{job["pcb"]}"'),)) with pytest.raises(RuntimeError, match='PCB_SESSION_ACTIVE'): execute() assert not events def test_real_windows_job_abort_preserves_native_like_child(tmp_path): """Exercise real Win32 job/handle semantics using harmless Python processes.""" import sys import time import uuid import win32api import win32con import win32process from cbb_refresh_verify.desktop_worker import DesktopWorker script = tmp_path / 'parent.py' pid_path = tmp_path / 'child.pid' script.write_text( 'import subprocess, sys, time\nfrom pathlib import Path\n' 'child = subprocess.Popen([sys.executable, "-c", "import time; time.sleep(30)"])\n' f'pid_file = Path({str(pid_path)!r})\n' 'pending = pid_file.with_suffix(".pending")\n' 'pending.write_text(str(child.pid)); pending.replace(pid_file)\n' 'time.sleep(30)\n', encoding='utf-8') worker = DesktopWorker([sys.executable, str(script)], 'CbbSafetyTest_' + uuid.uuid4().hex[:8]) child_handle = None closed = False try: deadline = time.monotonic() + 10 while not pid_path.exists() and time.monotonic() < deadline: time.sleep(.05) assert pid_path.exists(), 'Harmless child process failed to start' child_handle = win32api.OpenProcess( win32con.PROCESS_QUERY_INFORMATION | win32con.PROCESS_TERMINATE, False, int(pid_path.read_text())) worker.kill() worker.wait() worker.close() closed = True assert win32process.GetExitCodeProcess(child_handle) == 259 finally: if not closed: worker.kill() worker.close() if child_handle is not None: win32process.TerminateProcess(child_handle, 0) child_handle.Close()