import json
from pathlib import Path
import pytest
from cbb_refresh_verify import failed_session, mentor_adapter
def startup_fixture(tmp_path, monkeypatch):
from contextlib import nullcontext
import win32gui, win32process, win32event, win32con
from cbb_refresh_verify import native_repair_ui, residual_sessions
job = {'root': str(tmp_path), 'pcb': str(tmp_path/'PCB/CBB.pcb'),
'project': str(tmp_path/'CBB.prj'), 'lmc_file': str(tmp_path/'lib.lmc'),
'desktop': 'CbbVerify_test'}
diagnostics = tmp_path/'diagnostics'
diagnostics.mkdir()
(diagnostics/'icdb-recovery.json').write_text(json.dumps({
'error_code': 'ICDB_REPAIR_REQUIRED', 'scope': 'project',
'database_path': str(tmp_path/'database'), 'session': 'lost-session'}))
records = [(12, r'C:\Mentor\wg\ExpeditionPCB.exe',
f'ExpeditionPCB.exe "{job["pcb"]}" -ReusableCircuit', 11)]
monkeypatch.setattr(mentor_adapter, '_process_details', lambda _: list(records))
monkeypatch.setattr(residual_sessions, '_process_handle', lambda *a, **kw: nullcontext(123))
monkeypatch.setattr(residual_sessions, '_handle_identity', lambda h:
{'created_handle': 'original', 'image': r'C:\Mentor\wg\ExpeditionPCB.exe'})
monkeypatch.setattr(residual_sessions, '_process_windows', lambda pids: {12: []})
monkeypatch.setattr(win32event, 'WaitForSingleObject', lambda *a:
win32con.WAIT_TIMEOUT if records else win32con.WAIT_OBJECT_0)
monkeypatch.setattr(native_repair_ui, '_current_desktop_name', lambda: 'CbbVerify_test')
monkeypatch.setattr(win32gui, 'EnumWindows', lambda fn, arg: fn(100, arg))
monkeypatch.setattr(win32gui, 'EnumChildWindows', lambda *args: None)
monkeypatch.setattr(win32process, 'GetWindowThreadProcessId', lambda _: (1, 12))
monkeypatch.setattr(win32gui, 'IsWindowVisible', lambda _: True)
monkeypatch.setattr(win32gui, 'IsWindowEnabled', lambda _: True)
monkeypatch.setattr(win32gui, 'GetWindowText', lambda _: 'Expedition PCB')
monkeypatch.setattr(win32gui, 'GetClassName', lambda _: 'Afx:main')
messages = []
def post(hwnd, message, wparam, lparam):
messages.append((hwnd, message))
records.clear()
monkeypatch.setattr(win32gui, 'PostMessage', post)
return job, records, messages
@pytest.mark.parametrize('title', ['Expedition PCB', 'Expedition PCB - Reusable Block'])
def test_failed_startup_normally_closes_owned_empty_pcb(tmp_path, monkeypatch, title):
import win32con
import win32gui
job, records, messages = startup_fixture(tmp_path, monkeypatch)
monkeypatch.setattr(win32gui, 'GetWindowText', lambda _: title)
result = failed_session.close_failed_startup(job, 12, baseline_pids=(), timeout_seconds=0)
assert result['status'] == 'CLOSED'
assert not records
assert messages == [(100, win32con.WM_CLOSE)]
assert json.loads((tmp_path/'startup-close.json').read_text())['status'] == 'CLOSED'
@pytest.mark.parametrize('obstacle', ['baseline', 'wrong_path', 'path_prefix', 'desktop', 'address',
'dialog', 'document_title', 'mdi_document', 'disabled'])
def test_failed_startup_preserves_unconfirmed_or_busy_session(tmp_path, monkeypatch, obstacle):
import win32gui
from cbb_refresh_verify import native_repair_ui
job, records, messages = startup_fixture(tmp_path, monkeypatch)
baseline = ()
if obstacle == 'baseline': baseline = (12,)
if obstacle == 'wrong_path': records[0] = (12, records[0][1], 'other.pcb -ReusableCircuit', 11)
if obstacle == 'path_prefix':
records[0] = (12, records[0][1], f'pcb.exe "{job["pcb"]}.other" -ReusableCircuit', 11)
if obstacle == 'desktop': monkeypatch.setattr(native_repair_ui, '_current_desktop_name', lambda: 'Default')
if obstacle == 'address':
address = tmp_path/'database/cdbsvr/sAddress.adr'
address.parent.mkdir(parents=True)
address.write_text('owner')
if obstacle == 'dialog': monkeypatch.setattr(win32gui, 'GetClassName', lambda _: '#32770')
if obstacle == 'document_title': monkeypatch.setattr(win32gui, 'GetWindowText', lambda _: 'CBB.pcb - Expedition PCB')
if obstacle == 'mdi_document':
monkeypatch.setattr(win32gui, 'EnumChildWindows', lambda hwnd, fn, arg: fn(101, arg))
monkeypatch.setattr(win32gui, 'GetClassName', lambda hwnd: 'MDIClient' if hwnd == 101 else 'Afx:main')
monkeypatch.setattr(win32gui, 'GetWindow', lambda *args: 102)
if obstacle == 'disabled': monkeypatch.setattr(win32gui, 'IsWindowEnabled', lambda _: False)
if obstacle == 'no_diagnosis': (tmp_path/'diagnostics/icdb-recovery.json').unlink()
result = failed_session.close_failed_startup(job, 12, baseline_pids=baseline, timeout_seconds=0)
assert result['status'] == 'RETAINED'
assert records
assert not messages
def test_owned_empty_shell_closes_without_an_icdb_diagnosis(tmp_path, monkeypatch):
job, records, messages = startup_fixture(tmp_path, monkeypatch)
(tmp_path/'diagnostics/icdb-recovery.json').unlink()
result = failed_session.close_failed_startup(job, 12, timeout_seconds=0)
assert result['status'] == 'CLOSED' and not records and len(messages) == 1
def read_write_fixture(tmp_path, monkeypatch):
import win32gui, win32con
from cbb_refresh_verify.post_repair_consent import PROMPT_TEXT
job, records, messages = startup_fixture(tmp_path, monkeypatch)
(tmp_path/'diagnostics/icdb-recovery.json').unlink()
visible = {100, 200}
classes = {100: 'Afx:main', 200: '#32770', 201: 'Button', 202: 'Button', 203: 'Static'}
names = {100: 'Expedition PCB', 200: 'Expedition PCB', 201: 'Yes', 202: 'No', 203: PROMPT_TEXT}
identifiers = {201: 6, 202: 7, 203: 65535}
monkeypatch.setattr(win32gui, 'EnumWindows', lambda fn, arg: [fn(h, arg) for h in tuple(visible)])
monkeypatch.setattr(win32gui, 'EnumChildWindows', lambda h, fn, arg:
[fn(c, arg) for c in (201, 202, 203)] if h == 200 else None)
monkeypatch.setattr(win32gui, 'GetClassName', classes.__getitem__)
monkeypatch.setattr(win32gui, 'GetWindowText', names.__getitem__)
monkeypatch.setattr(win32gui, 'GetDlgCtrlID', identifiers.__getitem__)
monkeypatch.setattr(win32gui, 'IsWindowEnabled', lambda h: h != 100 or 200 not in visible)
monkeypatch.setattr(win32gui, 'IsWindowVisible', lambda h: h in visible or h in identifiers)
def post(hwnd, message, *_):
messages.append((hwnd, message))
if hwnd == 202 and message == win32con.BM_CLICK:
visible.remove(200)
elif hwnd == 100 and message == win32con.WM_CLOSE:
records.clear()
monkeypatch.setattr(win32gui, 'PostMessage', post)
return job, records, messages, names, visible
def test_captured_read_write_question_is_declined_and_own_empty_shell_exits(tmp_path, monkeypatch):
import win32con
job, records, messages, _, _ = read_write_fixture(tmp_path, monkeypatch)
# A pre-existing address must not prevent cancelling our own attempted open.
address = tmp_path/'database/cdbsvr/sAddress.adr'
address.parent.mkdir(parents=True)
address.write_text('existing foreign or stale address')
result = failed_session.close_failed_startup(job, 12, timeout_seconds=0)
assert result['status'] == 'CLOSED' and result['release']['safe_to_continue']
assert messages == [(202, win32con.BM_CLICK), (100, win32con.WM_CLOSE)]
assert not records and address.read_text() == 'existing foreign or stale address'
assert result['cancelled_prompt'] == 'read_write_access'
@pytest.mark.parametrize('obstacle', ['text', 'foreign_pid', 'baseline', 'wrong_path', 'desktop', 'stuck'])
def test_read_write_cancel_never_accepts_unconfirmed_or_unclosed_prompt(tmp_path, monkeypatch, obstacle):
import win32gui, win32process, win32con
from cbb_refresh_verify import native_repair_ui
job, records, messages, names, _ = read_write_fixture(tmp_path, monkeypatch)
if obstacle == 'text': names[203] += ' Different recovery operation.'
if obstacle == 'foreign_pid':
monkeypatch.setattr(win32process, 'GetWindowThreadProcessId', lambda h: (1, 99 if h == 200 else 12))
if obstacle == 'wrong_path': records[0] = (12, records[0][1], 'other.pcb -ReusableCircuit', 11)
if obstacle == 'desktop': monkeypatch.setattr(native_repair_ui, '_current_desktop_name', lambda: 'Default')
if obstacle == 'stuck':
monkeypatch.setattr(win32gui, 'PostMessage', lambda h, m, *_: messages.append((h, m)))
result = failed_session.close_failed_startup(job, 12,
baseline_pids=(12,) if obstacle == 'baseline' else (), timeout_seconds=0)
assert result['status'] == 'RETAINED' and records
assert messages == ([(202, win32con.BM_CLICK)] if obstacle == 'stuck' else [])
def test_version_choice_is_cancelled_without_selecting_or_confirming_a_version(tmp_path, monkeypatch):
import win32gui, win32con
from test_pcb_version_choice import captured
job, records, messages, _, visible = read_write_fixture(tmp_path, monkeypatch)
snapshot = captured()
children = [c for c in snapshot.controls if c.handle and c.handle != snapshot.hwnd]
mapping = {300+i: c for i, c in enumerate(children)}
monkeypatch.setattr(win32gui, 'EnumChildWindows', lambda h, fn, arg:
[fn(c, arg) for c in mapping] if h == 200 else None)
monkeypatch.setattr(win32gui, 'GetClassName', lambda h: mapping[h].class_name if h in mapping else
'#32770' if h == 200 else 'Afx:main')
monkeypatch.setattr(win32gui, 'GetWindowText', lambda h: mapping[h].name if h in mapping else
'Database Restoration' if h == 200 else 'Expedition PCB')
monkeypatch.setattr(win32gui, 'GetDlgCtrlID', lambda h: mapping[h].control_id)
cancel = next(h for h, c in mapping.items() if c.control_id == 2)
def post(h, m, *_):
messages.append((h, m))
if h == cancel: visible.remove(200)
elif h == 100: records.clear()
monkeypatch.setattr(win32gui, 'PostMessage', post)
result = failed_session.close_failed_startup(job, 12, timeout_seconds=0)
assert result['status'] == 'CLOSED' and result['cancelled_prompt'] == 'pcb_version_choice'
assert messages == [(cancel, win32con.BM_CLICK), (100, win32con.WM_CLOSE)]
def test_requested_close_without_exit_is_not_reported_closed(tmp_path, monkeypatch):
import win32gui
job, records, messages = startup_fixture(tmp_path, monkeypatch)
monkeypatch.setattr(win32gui, 'PostMessage', lambda hwnd, message, *_: messages.append((hwnd, message)))
result = failed_session.close_failed_startup(job, 12, timeout_seconds=0)
assert result['status'] == 'RETAINED'
assert 'STARTUP_EXIT_UNCONFIRMED' in result['detail']
assert len(messages) == 1
assert records
@pytest.mark.parametrize('exits', [True, False])
def test_after_owned_close_transient_empty_command_waits_for_exit(tmp_path, monkeypatch, exits):
from types import SimpleNamespace
import win32gui
job, records, messages = startup_fixture(tmp_path, monkeypatch)
ticks = [0.0]
def post(hwnd, message, *_):
messages.append((hwnd, message))
records[0] = (12, '', '', 11) # WMI during process teardown.
def advance(seconds):
ticks[0] += seconds
if exits: records.clear()
monkeypatch.setattr(win32gui, 'PostMessage', post)
monkeypatch.setattr(failed_session, 'time', SimpleNamespace(monotonic=lambda: ticks[0], sleep=advance))
result = failed_session.close_failed_startup(job, 12, timeout_seconds=1)
assert ticks[0] > 0 and len(messages) == 1
assert result['status'] == ('CLOSED' if exits else 'RETAINED')
assert 'STARTUP_PROCESS_UNCONFIRMED' not in result.get('detail', '')
@pytest.mark.parametrize('obstacle', ['address', 'dialog', 'process'])
def test_startup_close_waits_for_native_state_transitions(tmp_path, monkeypatch, obstacle):
from types import SimpleNamespace
import win32gui
job, records, messages = startup_fixture(tmp_path, monkeypatch)
ticks = [0]
address = tmp_path/'database/cdbsvr/sAddress.adr'
if obstacle == 'address':
address.parent.mkdir(parents=True)
address.write_text('owner')
if obstacle == 'dialog':
monkeypatch.setattr(win32gui, 'GetClassName',
lambda _: '#32770' if ticks[0] == 0 else 'Afx:main')
if obstacle == 'process':
monkeypatch.setattr(win32gui, 'PostMessage',
lambda hwnd, message, *_: messages.append((hwnd, message)))
def advance(seconds):
ticks[0] += seconds
if obstacle == 'address' and address.exists(): address.unlink()
if obstacle == 'process' and messages: records.clear()
monkeypatch.setattr(failed_session, 'time', SimpleNamespace(
monotonic=lambda: ticks[0], sleep=advance))
result = failed_session.close_failed_startup(job, 12, timeout_seconds=1)
assert ticks[0] > 0
assert result['status'] == 'CLOSED'
assert len(messages) == 1
assert not records
def test_worker_closes_startup_failure_before_document_identity(tmp_path, monkeypatch):
from test_verify_worker_stability import exercise_worker
job, events, execute = exercise_worker(tmp_path, monkeypatch)
job['desktop'] = 'CbbVerify_test'
def fail_open(*args, **kwargs):
raise RuntimeError('VERIFY_CANCELLED: database open failed')
monkeypatch.setattr('cbb_refresh_verify.pcb_bridge.wait_for_target_document', fail_open)
# Native process/window behavior is covered above; here verify the worker
# actually reaches startup cleanup instead of requiring a loaded document.
def close(job, pid, **kwargs):
kwargs['emit'](stage='startup_close_result', status='CLOSED', pcb_pid=pid)
return {'status': 'CLOSED'}
monkeypatch.setattr(failed_session, 'close_failed_startup', close, raising=False)
with pytest.raises(RuntimeError, match='VERIFY_CANCELLED'):
execute()
assert any(e['stage'] == 'startup_close_result' and e['pcb_pid'] == 2 for e in events)
assert not any(e['stage'] == 'save_start' for e in events)
def test_failed_startup_accepts_current_owned_database_failure_dialog(tmp_path, monkeypatch):
job, records, messages = startup_fixture(tmp_path, monkeypatch)
(tmp_path/'diagnostics/icdb-recovery.json').unlink()
(tmp_path/'dialogs.jsonl').write_text(json.dumps({
'pid': 12, 'phase': 'PCB_STARTING', 'error_code': 'MENTOR_DATABASE_LOAD_FAILED'})+'\n')
result = failed_session.close_failed_startup(job, 12, timeout_seconds=0)
assert result['status'] == 'CLOSED'
assert not records
@pytest.mark.parametrize('pid,phase', [(99, 'PCB_STARTING'), (12, 'SAVING')])
def test_unrelated_failure_record_is_not_needed_to_close_own_empty_shell(tmp_path, monkeypatch, pid, phase):
job, records, messages = startup_fixture(tmp_path, monkeypatch)
(tmp_path/'diagnostics/icdb-recovery.json').unlink()
(tmp_path/'dialogs.jsonl').write_text(json.dumps({
'pid': pid, 'phase': phase, 'error_code': 'MENTOR_DATABASE_LOAD_FAILED'})+'\n')
assert failed_session.close_failed_startup(job, 12, timeout_seconds=0)['status'] == 'CLOSED'
assert len(messages) == 1 and not records
@pytest.mark.parametrize('exits', [True, False])
def test_startup_close_waits_for_launcher_after_empty_pcb_exit(tmp_path, monkeypatch, exits):
from types import SimpleNamespace
job, records, messages = startup_fixture(tmp_path, monkeypatch)
ticks = [0.0]
launcher = SimpleNamespace(pid=11, poll=lambda: 0 if exits and ticks[0] >= .4 else None)
monkeypatch.setattr(failed_session, 'time', SimpleNamespace(
monotonic=lambda: ticks[0], sleep=lambda seconds: ticks.__setitem__(0, ticks[0]+seconds)))
result = failed_session.close_failed_startup(job, 12, launcher_process=launcher, timeout_seconds=1)
assert ticks[0] >= .4
assert result['status'] == ('CLOSED' if exits else 'RETAINED')
assert result['release']['launcher_exited'] is exits
assert result['release']['pcb_exited'] is True
assert len(messages) == 1
def test_startup_exit_does_not_hide_late_database_address(tmp_path, monkeypatch):
import win32gui
job, records, messages = startup_fixture(tmp_path, monkeypatch)
def close(*args):
records.clear()
address = tmp_path/'database/cdbsvr/sAddress.adr'
address.parent.mkdir(parents=True)
address.write_text('still owned')
monkeypatch.setattr(win32gui, 'PostMessage', close)
result = failed_session.close_failed_startup(job, 12, timeout_seconds=0)
assert result['status'] == 'RETAINED'
assert result['release']['addresses']
@pytest.mark.parametrize('window_class,title', [('CustomPrompt', 'Database action pending'),
('Afx:tool', ''), ('UAC_InputIndicatorOverlayWnd', 'Unknown prompt'), ('UAC Input Indicator', ' ')])
def test_enabled_empty_main_with_unaccounted_owned_window_is_never_closed(tmp_path, monkeypatch, window_class, title):
import win32gui
job, records, messages = startup_fixture(tmp_path, monkeypatch)
monkeypatch.setattr(win32gui, 'EnumWindows', lambda fn, arg: [fn(hwnd, arg) for hwnd in (100, 200)])
monkeypatch.setattr(win32gui, 'GetClassName', lambda hwnd: 'Afx:main' if hwnd == 100 else window_class)
monkeypatch.setattr(win32gui, 'GetWindowText', lambda hwnd: 'Expedition PCB' if hwnd == 100 else title)
result = failed_session.close_failed_startup(job, 12, timeout_seconds=0)
assert result['status'] == 'RETAINED' and not result['release']['safe_to_continue']
assert messages == [] and records
assert result['unknown_windows'] == [{'hwnd': 200, 'class': window_class, 'title': title, 'enabled': True}]
assert json.loads((tmp_path/'startup-close.json').read_text(encoding='utf-8'))['unknown_windows'] == result['unknown_windows']
def test_empty_title_known_uac_windows_are_accounted_for_before_normal_close(tmp_path, monkeypatch):
import win32gui, win32con
job, records, messages = startup_fixture(tmp_path, monkeypatch)
classes = {100: 'Afx:main', 200: 'UAC_InputIndicatorOverlayWnd', 201: 'UAC Input Indicator'}
monkeypatch.setattr(win32gui, 'EnumWindows', lambda fn, arg: [fn(hwnd, arg) for hwnd in classes])
monkeypatch.setattr(win32gui, 'GetClassName', classes.__getitem__)
monkeypatch.setattr(win32gui, 'GetWindowText', lambda hwnd: 'Expedition PCB' if hwnd == 100 else '')
result = failed_session.close_failed_startup(job, 12, timeout_seconds=0)
assert result['status'] == 'CLOSED' and messages == [(100, win32con.WM_CLOSE)]
assert result['unknown_windows'] == []
assert [entry['hwnd'] for entry in result['benign_auxiliary_windows']] == [200, 201]
def test_custom_prompt_must_disappear_before_main_close(tmp_path, monkeypatch):
from types import SimpleNamespace
import win32gui
job, records, messages = startup_fixture(tmp_path, monkeypatch)
ticks = [0.0]
monkeypatch.setattr(win32gui, 'EnumWindows', lambda fn, arg:
[fn(hwnd, arg) for hwnd in ((100, 200) if ticks[0] == 0 else (100,))])
monkeypatch.setattr(win32gui, 'GetClassName', lambda hwnd: 'Afx:main' if hwnd == 100 else 'CustomPrompt')
monkeypatch.setattr(win32gui, 'GetWindowText', lambda hwnd: 'Expedition PCB' if hwnd == 100 else 'Still processing')
monkeypatch.setattr(failed_session, 'time', SimpleNamespace(monotonic=lambda: ticks[0],
sleep=lambda seconds: ticks.__setitem__(0, ticks[0] + seconds)))
result = failed_session.close_failed_startup(job, 12, timeout_seconds=1)
assert result['status'] == 'CLOSED' and ticks[0] > 0
assert len(messages) == 1
@pytest.mark.parametrize('obstacle', ['', 'title', 'area', 'children', 'near_class'])
def test_only_exact_empty_zero_area_childless_ie_infrastructure_is_benign(tmp_path, monkeypatch, obstacle):
import win32gui, win32con
job, records, messages = startup_fixture(tmp_path, monkeypatch)
monkeypatch.setattr(win32gui, 'EnumWindows', lambda fn, arg: [fn(hwnd, arg) for hwnd in (100, 200)])
monkeypatch.setattr(win32gui, 'GetClassName', lambda hwnd: 'Afx:main' if hwnd == 100 else
'Internet Explorer_Hidden_other' if obstacle == 'near_class' else 'Internet Explorer_Hidden')
monkeypatch.setattr(win32gui, 'GetWindowText', lambda hwnd: 'Expedition PCB' if hwnd == 100 else
'Active prompt' if obstacle == 'title' else '')
monkeypatch.setattr(win32gui, 'GetWindowRect', lambda hwnd: (0, 0, 100, 50) if obstacle == 'area' else (0, 0, 0, 0))
monkeypatch.setattr(win32gui, 'EnumChildWindows', lambda hwnd, fn, arg:
fn(201, arg) if hwnd == 200 and obstacle == 'children' else None)
result = failed_session.close_failed_startup(job, 12, timeout_seconds=0)
if obstacle:
assert result['status'] == 'RETAINED' and messages == []
assert result['unknown_windows'][0]['hwnd'] == 200
else:
assert result['status'] == 'CLOSED' and messages == [(100, win32con.WM_CLOSE)]
entry = result['benign_auxiliary_windows'][0]
assert entry['class'] == 'Internet Explorer_Hidden' and entry['rect'] == [0, 0, 0, 0]
assert entry['children'] == []
@pytest.mark.parametrize('receipt', ['matching', 'late', 'different_operation', 'different_identity'])
def test_supervisor_no_lets_own_empty_pcb_close_with_address_remaining(tmp_path, monkeypatch, receipt):
import win32con
job, records, messages, _, visible = read_write_fixture(tmp_path, monkeypatch)
job['operation_id'] = 'verify-owned'
address = tmp_path/'database/cdbsvr/sAddress.adr'
address.parent.mkdir(parents=True)
address.write_text('existing address')
snapshot = failed_session._startup_snapshot(200, 12).to_record()
from cbb_refresh_verify import residual_sessions
monkeypatch.setattr(residual_sessions, '_force_ownership', lambda *_: {
'owner_sid': 'S-1-5-21-test', 'session_id': 1})
owner = {'pid': 12, 'owner_sid': 'S-1-5-21-test', 'session_id': 1,
'image': records[0][1], 'created_handle': 'reused' if receipt == 'different_identity' else 'original'}
(tmp_path/'pcb-open-user-choice.json').write_text(json.dumps(dict(
operation_id='another-operation' if receipt == 'different_operation' else job['operation_id'],
desktop=job['desktop'], project=job['project'], pcb=job['pcb'],
library=job['lmc_file'], choice='skip', snapshot=snapshot, owner={'target': owner})))
visible.remove(200)
def record_acknowledgement():
(tmp_path/'dialogs.jsonl').write_text(json.dumps(dict(
snapshot, action='user_confirmed_pcb_open', error_code='PCB_OPEN_SKIPPED',
accepted_control=[7]))+'\n')
if receipt == 'late':
from types import SimpleNamespace
elapsed = 0.0
def advance(seconds):
nonlocal elapsed
elapsed += seconds
if elapsed < 0.3:
record_acknowledgement()
monkeypatch.setattr(failed_session, 'time',
SimpleNamespace(monotonic=lambda: elapsed, sleep=advance))
else:
record_acknowledgement()
result = failed_session.close_failed_startup(
job, 12, timeout_seconds=0 if receipt == 'different_operation' else 1)
if receipt in {'different_operation', 'different_identity'}:
assert result['status'] == 'RETAINED' and records and not messages
return
assert result['status'] == 'CLOSED'
assert result['cancelled_prompt'] == 'read_write_access'
assert result['release']['addresses'] == [str(address)]
assert result['release']['resource_release_confirmed'] is False
assert messages == [(100, win32con.WM_CLOSE)]
assert not records and address.is_file()