"""Structured Expedition PCB COM bridge primitives.
The bridge uses only interfaces confirmed in Mentor's registered type
libraries. It never relies on window titles or foreground-window state.
"""
from __future__ import annotations
import os
from pathlib import Path
import time
class PcbBridgeError(RuntimeError):
def __init__(self, error_code: str, detail: str) -> None:
self.error_code = str(error_code)
self.detail = str(detail)
super().__init__(self.detail)
class AutomationLicenseError(PcbBridgeError):
def __init__(self, error_code: str, detail: str, *, fallback_allowed: bool) -> None:
self.fallback_allowed = bool(fallback_allowed)
super().__init__(error_code, detail)
_UNAVAILABLE_HRESULTS = {
-2147221164, # REGDB_E_CLASSNOTREG
-2146959355, # CO_E_SERVER_EXEC_FAILURE
-2147023174, # RPC_S_SERVER_UNAVAILABLE
}
def _hresult(error):
value = getattr(error, 'hresult', None)
if value is None:
arguments = getattr(error, 'args', ())
value = arguments[0] if arguments and isinstance(arguments[0], int) else None
return value
def validate_document(document, license_factory, *, emit=lambda **event: None):
"""Acquire and apply an Expedition automation token without exposing it."""
try:
key = document.Validate(0)
emit(stage='license_key_requested')
except Exception as error:
raise AutomationLicenseError(
'AUTOMATION_LICENSE_KEY_FAILED', f'无法取得 PCB 授权 key: {error}',
fallback_allowed=False,
) from error
try:
licensing = license_factory()
token = licensing.GetToken(key)
emit(stage='license_token_received')
except Exception as error:
fallback_allowed = _hresult(error) in _UNAVAILABLE_HRESULTS
raise AutomationLicenseError(
'AUTOMATION_LICENSE_UNAVAILABLE' if fallback_allowed else 'AUTOMATION_LICENSE_TOKEN_FAILED',
f'无法取得 PCB automation token: {error}',
fallback_allowed=fallback_allowed,
) from error
try:
document.Validate(token)
emit(stage='document_validated')
except Exception as error:
raise AutomationLicenseError(
'AUTOMATION_LICENSE_REJECTED', f'PCB automation token 被拒绝: {error}',
fallback_allowed=False,
) from error
def _same_path(first, second) -> bool:
return os.path.normcase(os.path.abspath(str(first))) == os.path.normcase(os.path.abspath(str(second)))
def require_document_identity(document, job):
expected_project = Path(job['project'])
expected_pcb = Path(job['pcb'])
try:
integration = document.ProjectIntegration
project_file = str(integration.ProjectFile)
document_name = str(document.Name)
except Exception as error:
raise PcbBridgeError('PCB_IDENTITY_UNAVAILABLE', f'PCB 文档身份不可读: {error}') from error
if not _same_path(project_file, expected_project) or document_name.casefold() != expected_pcb.name.casefold():
raise PcbBridgeError(
'PCB_IDENTITY_MISMATCH',
f'当前 PCB 工程身份不符: project={project_file}; document={document_name}',
)
return integration
def wait_for_target_document(job, app_provider, *, process_alive, emit=lambda **event: None,
error_reader=None, sleep=time.sleep):
"""Wait for the exact launched document; the parent process owns timeout."""
last_observation = None
while process_alive():
if error_reader is not None:
detail = error_reader()
if detail:
raise PcbBridgeError('PCB_STARTUP_FAILED', detail)
try:
app = app_provider()
document = app.ActiveDocument
if not document:
observation = ('PCB_DOCUMENT_NOT_READY', 'COM 已连接,尚无目标文档')
if observation != last_observation:
emit(stage='pcb_document_wait', error_code=observation[0], detail=observation[1])
last_observation = observation
if document:
try:
integration = require_document_identity(document, job)
except PcbBridgeError as error:
observation = (error.error_code, error.detail)
if observation != last_observation:
emit(stage='identity_wait', error_code=error.error_code, detail=error.detail)
last_observation = observation
else:
emit(stage='identity_verified', project=str(integration.ProjectFile),
document=str(document.Name))
return app, document, integration
except PcbBridgeError:
raise
except Exception as error:
observation = ('COM_NOT_READY', str(error))
if observation != last_observation:
# COM registration is an internal attach wait, not a user
# operation. Keep the transient detail out of the workflow
# event stream; a final attach failure still raises below.
last_observation = observation
sleep(.25)
raise PcbBridgeError('PCB_EXITED_BEFORE_COM', 'PCB 在 COM 文档就绪前退出')
def execution_outcome(*, save_complete: bool, pcb_exited: bool,
fatal_error: str = '') -> dict[str, object]:
if fatal_error:
code, _, detail = str(fatal_error).partition(':')
return {'status': 'FAIL', 'error_code': code.strip() or 'FATAL_DIALOG',
'stderr': detail.strip() or str(fatal_error), 'safe_to_continue': True}
if not save_complete:
return {'status': 'FAIL', 'error_code': 'SAVE_NOT_CONFIRMED',
'stderr': '保存/关闭未完成', 'safe_to_continue': True}
if not pcb_exited:
return {'status': 'FAIL', 'error_code': 'PCB_EXIT_NOT_CONFIRMED',
'stderr': '保存后未确认 PCB 退出', 'safe_to_continue': True}
return {'status': 'PASS', 'stdout': 'Project Integration 已同步;保存、关闭和 PCB 退出均已确认。'}