Files
dxdesigner-part-replacement/docs/testing/evidence/2026-11-13-pr27/diagnose-empty-cad.py
T
阿白叔 a0f0a4b232
Core regression / Python core, intervention UI and release configuration (push) Successful in 3m52s
Core regression / JavaScript syntax (push) Successful in 5s
Core regression / Python core, intervention UI and release configuration (pull_request) Successful in 4m13s
Core regression / JavaScript syntax (pull_request) Successful in 9s
test: make Windows retry fixture portable and retain live diagnostics
2026-11-13 16:30:07 +08:00

58 lines
2.7 KiB
Python

"""Measure empty owned CAD without changing product or existing acceptance data."""
import faulthandler
import json
from pathlib import Path
import sys
import time
import traceback
out = Path(__file__).resolve().parent
repo = out.parents[1]
sys.path.insert(0, str(repo / 'src'))
if len(sys.argv) > 1:
action, evidence, pid = sys.argv[1:]
trace_path = Path(str(evidence) + '.' + action + '.trace.jsonl')
with trace_path.open('w', encoding='utf-8', buffering=1) as log, Path(str(trace_path) + '.fault.txt').open('w') as fault:
def record(stage, **details):
log.write(json.dumps(dict(ns=time.time_ns(), stage=stage, **details)) + '\n')
record('helper-entry')
faulthandler.dump_traceback_later(5, repeat=True, file=fault)
from dx_productivity.trial_task_center.isolated_cad import native_action
record('helper-imported')
def trace(frame, event, arg):
if event == 'line' and (frame.f_code.co_name in {'_native_action', 'verify_application', 'project_file_path'}):
record(frame.f_code.co_name, line=frame.f_lineno)
return trace
sys.settrace(trace)
try:
result = native_action(action, Path(evidence), int(pid))
finally:
sys.settrace(None)
faulthandler.cancel_dump_traceback_later()
record('helper-result', result=result)
raise SystemExit(result)
from dx_productivity.trial_task_center import isolated_cad
root = out / 'empty-cad-diagnostic'
assert not root.exists()
isolated_cad._helper_command = lambda action, evidence, pid: (sys.executable, '-X', 'utf8', str(Path(__file__).resolve()), action, str(evidence), str(pid))
session = isolated_cad.IsolatedCadSession(root)
original_wait = session._wait_process
# Diagnostic only: observe the eventual exit, never count this as product acceptance.
session._wait_process = lambda process, timeout, phase: original_wait(process, 120, phase)
record = dict(status='running', started_ns=time.time_ns(), diagnostic_wait_seconds=120, project_opened=False)
try:
with session:
record['startup_ns'] = time.time_ns()
print('empty CAD attached', flush=True)
session.checkpoint(root / 'checkpoint.json')
record['checkpoint_ns'] = time.time_ns()
print('empty CAD checkpoint complete', flush=True)
record.update(status='completed', finished_ns=time.time_ns(), cad_record=session.record)
except BaseException:
record.update(status='failed_preserved', failure=traceback.format_exc(), finished_ns=time.time_ns(), cad_record=session.record)
raise
finally:
(out / 'empty-cad-diagnostic.json').write_text(json.dumps(record, ensure_ascii=False, indent=2), encoding='utf-8')