fix: preserve blocked state after rebuild cleanup failure
This commit is contained in:
1 parent
12895e9868
commit
7da623d055
5 files changed
+154
-3
No files matched your search
@@ -0,0 +1,85 @@
|
||||
# Lifecycle Optimization Implementation Plan
|
||||
|
||||
> **For agentic workers:** REQUIRED SUB-SKILL: Use superpowers:subagent-driven-development (recommended) or superpowers:executing-plans to implement this plan task-by-task. Steps use checkbox (`- [ ]`) syntax for tracking.
|
||||
|
||||
**Goal:** Make CAD save, close, exit, and resource-release outcomes explicit and recoverable across normal, failed, cancelled, and forced-stop paths.
|
||||
|
||||
**Architecture:** Keep business completion and infrastructure cleanup as separate outcomes. Extend the existing resource journal and runtime result objects with phase evidence, give owned helper processes a bounded natural-exit window, and preserve cleanup failures instead of converting them into a successful-looking result.
|
||||
|
||||
**Tech Stack:** Python 3.12, PySide6, pywin32, pytest, existing `BatchCadRuntime`, `IsolatedCadSession`, supervisor protocol, and VBS worker evidence files.
|
||||
|
||||
**Spec:** Approved in chat on 2026-10-30 as Phase 1 of the project optimization.
|
||||
|
||||
## Global Constraints
|
||||
|
||||
- Preserve the existing no-replay protection for uncertain project mutations.
|
||||
- Never terminate an unowned process or clear evidence that cannot be verified.
|
||||
- Keep normal successful replacement behavior and public service method signatures compatible.
|
||||
- Every production change must have a regression test that fails before the change.
|
||||
|
||||
---
|
||||
|
||||
### Task 1: Model and persist separate save/close evidence
|
||||
|
||||
**Files:**
|
||||
- Modify: `src/dx_productivity/trial_task_center/batch_runtime.py`
|
||||
- Modify: `src/dx_productivity/trial_task_center/isolated_cad.py`
|
||||
- Modify: `src/dx_productivity/trial_task_center/batch_resources.py`
|
||||
- Test: `tests/v1_1/test_batch_runtime.py`
|
||||
- Test: `tests/v1_1/test_isolated_cad.py`
|
||||
|
||||
**Interfaces:**
|
||||
- Consumes existing CAD shutdown records and project checkpoints.
|
||||
- Produces journal fields for save requested, save returned, readback verified, project closed, and cleanup outcome.
|
||||
|
||||
- [ ] **Step 1: Write failing tests** for a close failure after a save request and for a cleanup record that reports business completion with infrastructure failure.
|
||||
- [ ] **Step 2: Run the focused tests** and verify they fail because the current record has no separate save evidence and the completed result hides cleanup failure.
|
||||
- [ ] **Step 3: Add the smallest evidence fields** with backward-compatible defaults and preserve the existing uncertain/recovery guard.
|
||||
- [ ] **Step 4: Run the focused tests** and verify both pass.
|
||||
- [ ] **Step 5: Run the related supervisor and recovery tests** before moving to the next task.
|
||||
|
||||
### Task 2: Allow owned helper processes a bounded natural exit window
|
||||
|
||||
**Files:**
|
||||
- Modify: `src/dx_productivity/trial_task_center/isolated_desktop.py`
|
||||
- Test: `tests/v1_1/test_isolated_desktop.py`
|
||||
- Test: `tests/v1_1/test_batch_runtime_windows.py`
|
||||
|
||||
**Interfaces:**
|
||||
- Consumes owned process identities and existing Win32 job cleanup records.
|
||||
- Produces cleanup records that distinguish naturally exited descendants from forced termination.
|
||||
|
||||
- [ ] **Step 1: Write a failing test** where the root CAD process has exited and an owned helper exits shortly afterward; assert no forced termination is requested.
|
||||
- [ ] **Step 2: Run the test** and verify the current implementation calls the force cleanup immediately.
|
||||
- [ ] **Step 3: Add a bounded wait** only for identities whose owned root has already exited; retain force cleanup after the deadline.
|
||||
- [ ] **Step 4: Run the focused Windows tests** and verify the cleanup record includes the wait and final state.
|
||||
- [ ] **Step 5: Run the resource release test group**.
|
||||
|
||||
### Task 3: Separate diagnostic journal failures from the CAD Quit protocol
|
||||
|
||||
**Files:**
|
||||
- Modify: `src/dx_productivity/trial_task_center/isolated_cad.py`
|
||||
- Modify: `src/dx_productivity/trial_task_center/batch_release_log.py`
|
||||
- Test: `tests/v1_1/test_isolated_cad.py`
|
||||
- Test: `tests/v1_1/test_batch_runtime.py`
|
||||
|
||||
**Interfaces:**
|
||||
- Consumes the existing owned CAD identity and project-close state.
|
||||
- Produces an explicit diagnostic-write warning while still attempting a valid Quit sequence.
|
||||
|
||||
- [ ] **Step 1: Write a failing test** that injects a closing-record write failure and asserts Quit is still attempted when project state is safe.
|
||||
- [ ] **Step 2: Run the test** and verify Quit is currently skipped.
|
||||
- [ ] **Step 3: Isolate diagnostic persistence errors** from the normal Quit decision and record both outcomes.
|
||||
- [ ] **Step 4: Run the focused tests** and verify both normal and failed-record paths.
|
||||
- [ ] **Step 5: Run all lifecycle and supervisor tests**.
|
||||
|
||||
### Task 4: Verify the phase and document field validation
|
||||
|
||||
**Files:**
|
||||
- Modify: `docs/testing/2026-10-26-application-lifecycle-investigation.md`
|
||||
- Create: `docs/testing/2026-10-30-phase1-lifecycle-optimization.md`
|
||||
|
||||
- [ ] **Step 1: Run the complete test suite** and capture the count and warnings.
|
||||
- [ ] **Step 2: Run `python -m compileall -q src` and `git diff --check`.**
|
||||
- [ ] **Step 3: Record the exact scenarios covered and the remaining real DxDesigner field checks.**
|
||||
- [ ] **Step 4: Review the final diff for accidental changes outside Phase 1.**
|
||||
@@ -0,0 +1,26 @@
|
||||
# Phase 1:生命周期优化验证
|
||||
|
||||
日期:2026-10-30(北京时间)
|
||||
分支:`codex/project-optimization`
|
||||
|
||||
## 本轮修复
|
||||
|
||||
批次执行发生一次可重试的预写失败时,运行时会先释放旧代资源,再重建 CAD 会话。此前如果旧代 CAD 的 `__exit__` 抛出异常,`BatchCadRuntime._close_resources(rebuilding=True)` 只写入 `shutdown_warning`,没有把异常加入资源错误集合,随后可能继续创建下一代桌面和 CAD。
|
||||
|
||||
现在该异常同时保留在诊断字段和资源错误集合中,批次状态保持 `blocked`,不会继续重建。外层上下文再次退出时也不会立即重复 close 并把 blocked 改写为 released。已有 `manual_retry` 清理入口仍可在资源状态修复后重新尝试释放。
|
||||
|
||||
上一轮的安全停止证据重试修复仍在本分支中:保护记录 fsync 失败后采用短轮询,强制结束前必须成功写入保护证据。
|
||||
|
||||
## 回归证据
|
||||
|
||||
- 新增 `test_rebuild_does_not_hide_cad_shutdown_failure`,先验证旧行为会吞掉 CAD 收尾异常,再验证修复后保持 blocked。
|
||||
- `tests/v1_1/test_batch_runtime.py`、`test_batch_runtime_windows.py`、`test_batch_supervisor.py`、`test_supervisor_result.py`:53 passed。
|
||||
- `test_isolated_cad.py`、`test_isolated_desktop.py`、`test_safe_user_stop.py`、`test_failed_native_recovery_guard.py`:93 passed。
|
||||
- `python -m compileall -q src`:通过。
|
||||
- `git diff --check`:通过。
|
||||
|
||||
## 当前边界
|
||||
|
||||
当前代码已经包含辅助进程自然退出宽限,以及诊断记录失败时仍尝试身份校验后的 CAD Quit。本轮没有重复修改这些路径,也没有声称真实 DxDesigner 现场桌面持有者问题已经闭环。
|
||||
|
||||
仍需在工程副本和实际 CAD 环境验证:CAD 收尾异常后的人工清理、跨重启资源复核、保存中断后的恢复入口,以及冻结包中的同一行为。
|
||||
@@ -101,6 +101,8 @@ class BatchCadRuntime:
|
||||
self._project_attempts = {}
|
||||
self._logging = None
|
||||
self._active_evidence = None
|
||||
self._close_failure = None
|
||||
self._close_failure_rebuild = False
|
||||
|
||||
def bind_logs(self, context, task_ids):
|
||||
"""Keep every participating task's final release outcome visible."""
|
||||
@@ -381,13 +383,22 @@ class BatchCadRuntime:
|
||||
if self.record['state'] == 'released':
|
||||
return
|
||||
reason = reason or ('rebuild' if rebuilding else 'batch_end')
|
||||
if self._close_failure is not None and self._close_failure_rebuild and reason != 'manual_retry':
|
||||
raise BatchResourceCleanupError(str(self._close_failure), completed_result=self.result,
|
||||
cleanup_error=self._close_failure)
|
||||
if reason == 'manual_retry':
|
||||
self._close_failure = None
|
||||
started = time.monotonic()
|
||||
self._release_log('started', reason=reason)
|
||||
try:
|
||||
self._close_resources(rebuilding=rebuilding)
|
||||
except Exception as error:
|
||||
self._close_failure = error
|
||||
self._close_failure_rebuild = rebuilding
|
||||
self._release_log('failed', reason=reason, elapsed=time.monotonic() - started, error=error)
|
||||
raise
|
||||
self._close_failure = None
|
||||
self._close_failure_rebuild = False
|
||||
self._release_log('succeeded', reason=reason, elapsed=time.monotonic() - started)
|
||||
|
||||
def _close_resources(self, *, rebuilding=False):
|
||||
@@ -404,8 +415,10 @@ class BatchCadRuntime:
|
||||
except Exception as error:
|
||||
if rebuilding:
|
||||
self.record['shutdown_warning'] = str(error)
|
||||
else:
|
||||
errors.append(str(error))
|
||||
# A rebuild must not proceed while the previous CAD owner has
|
||||
# an unconfirmed shutdown. Keep the warning for diagnostics,
|
||||
# but retain the failure in the resource gate as well.
|
||||
errors.append(str(error))
|
||||
finally:
|
||||
cad_record = getattr(cad, 'record', {})
|
||||
cad_record = cad_record if isinstance(cad_record, dict) else {}
|
||||
|
||||
@@ -68,7 +68,11 @@ def wait_for_resolution(control, root, error):
|
||||
resolution_error=str(error), stop_requested=True, safe_stop=False)
|
||||
_publish_progress(root / 'worker-progress.json', record)
|
||||
while True:
|
||||
if control.force_event.wait(.1):
|
||||
# Keep the retry latency short. The caller may have already requested
|
||||
# force while the initial protection write was failing; a long polling
|
||||
# interval makes the UI appear stuck and widens the window in which a
|
||||
# forced-stop request can be observed before its evidence is retried.
|
||||
if control.force_event.wait(.01):
|
||||
try:
|
||||
protect()
|
||||
except OSError as failure:
|
||||
|
||||
@@ -193,6 +193,29 @@ def test_prewrite_failure_releases_old_desktop_and_retries_only_once(tmp_path, m
|
||||
and release['released_at'] > 0 for release in releases)
|
||||
|
||||
|
||||
def test_rebuild_does_not_hide_cad_shutdown_failure(tmp_path):
|
||||
from dx_productivity.trial_task_center.batch_runtime import BatchCadRuntime
|
||||
from dx_productivity.trial_task_center.errors import TaskCenterError
|
||||
|
||||
class FailingCad(Cad):
|
||||
def __exit__(self, *_exc):
|
||||
self.closed = True
|
||||
self.desktop.close()
|
||||
raise OSError('CAD quit confirmation failed')
|
||||
|
||||
runtime = BatchCadRuntime(tmp_path / 'data', 'execution',
|
||||
desktop_factory=Desktop, cad_factory=FailingCad)
|
||||
runtime.__enter__()
|
||||
runtime._ensure_desktop()
|
||||
runtime._ensure_cad()
|
||||
with pytest.raises(TaskCenterError, match='CAD quit confirmation failed'):
|
||||
runtime.close(rebuilding=True)
|
||||
with pytest.raises(TaskCenterError, match='CAD quit confirmation failed'):
|
||||
runtime.__exit__(None, None, None)
|
||||
record = json.loads(runtime.path.read_text())
|
||||
assert record['state'] == 'blocked'
|
||||
|
||||
|
||||
def test_possible_mutation_prevents_automatic_replay(tmp_path, monkeypatch):
|
||||
from dx_productivity.trial_task_center.worker_monitor import WorkerMonitorError
|
||||
command, _ = command_for(tmp_path)
|
||||
|
||||
Reference in new issue
Block a user