# DxDesigner 7.9.5 Parameter Presentation Transfer Design
|
|
|
|
## 1. Purpose
|
|
|
|
This document extends the existing DxDesigner 7.9.5 multi-project part
|
|
replacement design. The replacement remains a native `Replace Part` operation
|
|
with `Library Wins`, but it now has one controlled post-replacement step:
|
|
|
|
- copy the new symbol's exact `Part Label` value into the instance `Value`;
|
|
- preserve presentation metadata for parameters that existed on the old
|
|
instance and have an unambiguous same-name parameter on the new instance;
|
|
- never copy an old ordinary parameter value into the new instance.
|
|
|
|
The material identifier remains the `Part Number` attribute. Values such as
|
|
`4300-CA2260-A300` are examples, not a syntax restriction. Identity comparison
|
|
trims surrounding whitespace and is case-insensitive, while reports preserve
|
|
the original spelling.
|
|
|
|
This document supersedes only the attribute semantics, snapshot fields, Apply
|
|
steps, and verification rules described below. All existing requirements for
|
|
backup, native replacement, RefDes, placement, origin, units, pins,
|
|
connectivity, unrelated objects, recovery, evidence correlation, and
|
|
evaluation-only release status continue to apply.
|
|
|
|
## 2. Non-Goals
|
|
|
|
- Rebuilding a symbol or its pins through scripts.
|
|
- Copying old ordinary parameter values over new library values.
|
|
- Creating parameters that existed only on the old symbol.
|
|
- Reconnecting, moving, creating, or deleting wires.
|
|
- Using UI coordinates, `SendKeys`, or timing delays.
|
|
- Claiming an unsupported 7.9.5 property API without probe and live evidence.
|
|
|
|
## 3. Parameter Identity
|
|
|
|
Parameter names are normalized by trimming surrounding whitespace and applying
|
|
a case-insensitive comparison. The original name remains in evidence and
|
|
reports.
|
|
|
|
For each component and owner scope:
|
|
|
|
- one old and one new parameter with the same normalized name form an
|
|
unambiguous match;
|
|
- an old-only parameter is not recreated and is reported as removed;
|
|
- a new-only parameter keeps its new-library value and presentation defaults;
|
|
- duplicate normalized names on either side are ambiguous and receive no
|
|
automatic presentation transfer.
|
|
|
|
An ambiguous ordinary parameter creates a warning. An ambiguous `Part Label`
|
|
or `Value` prevents the mandatory `Value` operation and is therefore a hard
|
|
failure.
|
|
|
|
## 4. Trusted Pre-Replacement Capture
|
|
|
|
The bridge must capture and durably publish a complete trusted snapshot before
|
|
it selects components or opens native Replace Part. Capture occurs separately
|
|
for every matched logical component, every placed unit, and every existing
|
|
parameter instance. It may not be reconstructed from post-replacement state.
|
|
|
|
The controller must correlate this snapshot with the job, project, mapping,
|
|
command identifier, active-project identity, expected component count, and
|
|
current project fingerprint. If any matched component, unit, parameter value,
|
|
or required presentation field cannot be read unambiguously, the bridge stops
|
|
before replacement and reports the exact object and field.
|
|
|
|
Each parameter snapshot contains:
|
|
|
|
- original and normalized parameter name;
|
|
- current value, for reporting and rollback comparison only;
|
|
- logical component key and RefDes;
|
|
- owner scope and placed-unit identity, when the parameter is unit-owned;
|
|
- visible state;
|
|
- schematic text origin or position in invariant coordinates;
|
|
- rotation or orientation;
|
|
- horizontal and vertical justification or the equivalent alignment values;
|
|
- color;
|
|
- font family or style identifier when exposed;
|
|
- text size or height/width fields exposed by the certified route; and
|
|
- any additional stable presentation field explicitly named by the
|
|
compatibility profile.
|
|
|
|
The schema distinguishes component/unit placement coordinates from parameter
|
|
text coordinates. A parameter coordinate must never substitute for component
|
|
origin or component position evidence.
|
|
|
|
## 5. Apply Sequence
|
|
|
|
For one mapping group in one project, the bridge performs these ordered steps:
|
|
|
|
1. Validate the correlated command, active project, saved state, inventory
|
|
fingerprint, certification, and expected count.
|
|
2. Capture and durably publish the trusted pre-replacement component, unit,
|
|
pin, network, ordinary parameter, `Part Label`, and `Value` evidence.
|
|
3. Select exactly the logical components identified by the controller.
|
|
4. Invoke or request the native `Replace Part` dialog.
|
|
5. Require the exact target `Part Number` and `Library Wins`.
|
|
6. Observe native completion through the certified route or explicit manual
|
|
continuation; no blind delay is allowed.
|
|
7. Re-enumerate the replaced objects and verify their target identity.
|
|
8. Read the new symbol's exact `Part Label` value.
|
|
9. Write that exact value to the instance `Value` and read it back.
|
|
10. Transfer presentation metadata for unambiguous same-name parameters.
|
|
11. Export the post-transfer snapshot and a field-level transfer result.
|
|
12. Let Python run hard verification and produce warnings/differences.
|
|
|
|
No ordinary parameter value assignment is permitted in step 10. `Library
|
|
Wins` remains authoritative for ordinary parameter values.
|
|
|
|
## 6. Value Rule
|
|
|
|
`Value` is the only parameter whose value is written by the post-replacement
|
|
step.
|
|
|
|
- Source: the exact new-symbol `Part Label` value.
|
|
- Destination: the replaced instance's `Value` parameter.
|
|
- Comparison: exact string equality after the write; no case folding or
|
|
whitespace normalization changes the stored value.
|
|
- Presentation: inherit all certified presentation fields from the old
|
|
instance's `Value` when it existed unambiguously.
|
|
- Default presentation: when the old instance had no `Value`, retain the new
|
|
symbol's default `Value` presentation.
|
|
|
|
Missing, empty, ambiguous, unreadable, or unwritable `Part Label`; missing,
|
|
ambiguous, or unwritable `Value`; a write error; or a read-back mismatch is a
|
|
hard failure. The project cannot be saved and the existing verified Undo or
|
|
close-without-save recovery path is required.
|
|
|
|
Failure to copy only a `Value` presentation field is a warning, not a hard
|
|
failure, provided the exact `Value` content was written and read back.
|
|
|
|
## 7. Ordinary Parameter Presentation Transfer
|
|
|
|
For every unambiguous same-name ordinary parameter, the bridge attempts to
|
|
copy each presentation field from the trusted old snapshot to the new
|
|
parameter. Values remain those supplied by the new library.
|
|
|
|
Each failed field produces a `parameter_style_inheritance_failed` warning with
|
|
job, project, mapping, logical key, RefDes, unit or owner scope, parameter name,
|
|
field name, old presentation value, observed new value, API route, and error.
|
|
The warning does not trigger Undo and does not by itself block save.
|
|
|
|
The reports also distinguish:
|
|
|
|
- `parameter_removed_by_new_symbol`;
|
|
- `parameter_added_by_new_symbol`;
|
|
- `parameter_value_changed_by_library`;
|
|
- `parameter_name_ambiguous`; and
|
|
- successfully inherited presentation fields.
|
|
|
|
## 8. Verification and Recovery
|
|
|
|
Hard verification still requires the exact target `Part Number`, component
|
|
count, RefDes, hierarchy, unit set, component origin and position, rotation,
|
|
mirror state, pin-number set, pin coordinates, pin-to-net identity, and no
|
|
unrelated component changes.
|
|
|
|
It additionally requires:
|
|
|
|
- one nonempty, unambiguous new `Part Label` per replaced instance;
|
|
- exact `Value == Part Label` after the write and in the persisted reread; and
|
|
- no ordinary parameter value assignment performed by the transfer adapter.
|
|
|
|
Presentation warnings remain visible at the project save gate and in CSV, JSON,
|
|
and HTML reports. They do not override a hard verification result.
|
|
|
|
If any hard condition fails, Undo must be verified against the complete trusted
|
|
pre-replacement snapshot, including component/unit geometry, connectivity,
|
|
parameter values, and parameter presentation. If exact Undo cannot be proven,
|
|
the project must be closed without saving or restored from the verified backup.
|
|
|
|
## 9. Compatibility Profile
|
|
|
|
The read-mostly probe records the actual 7.9.5 routes and types for:
|
|
|
|
- enumerating parameter instances and their owner scope;
|
|
- reading `Part Label` and `Value`;
|
|
- writing and reading back `Value`;
|
|
- reading and writing each supported presentation field; and
|
|
- distinguishing component placement coordinates from parameter text
|
|
coordinates.
|
|
|
|
Production Apply is blocked unless the `Part Label` read route and `Value`
|
|
write/read-back routes are live-certified. An unavailable ordinary
|
|
presentation field disables only that field's automatic transfer and produces
|
|
an explicit warning/capability result.
|
|
|
|
The profile promotion evidence must identify the exact DxDesigner 7.9.5 build,
|
|
central-library identity or fingerprint, disposable fixture, mapping, route,
|
|
field type, observed before/after values, tester, date, and evidence hashes.
|
|
|
|
## 10. Protocol and Modules
|
|
|
|
The snapshot protocol advances to format version 3. Version 3 adds structured
|
|
parameter instances and presentation metadata. Version 1 lacks independent
|
|
component origin evidence and remains unsafe. Version 2 lacks parameter
|
|
presentation evidence and cannot authorize the new Apply workflow. Existing
|
|
version 1 or 2 jobs must be rejected with a stable re-inventory-required error;
|
|
they are never silently upgraded.
|
|
|
|
Responsibilities remain separated:
|
|
|
|
- Python domain/protocol modules define immutable parameter and presentation
|
|
evidence.
|
|
- A dedicated Python parameter-transfer policy module matches names, classifies
|
|
differences, and verifies results without accessing DxDesigner.
|
|
- A dedicated ASCII-only VBScript parameter-transfer adapter performs the
|
|
certified `Part Label`, `Value`, and presentation operations.
|
|
- The bridge coordinates selection, native replacement, adapter invocation,
|
|
and evidence publication, but does not decide warning or save policy.
|
|
- Controller/operator modules consume correlated results and preserve the
|
|
existing save and recovery gates.
|
|
|
|
## 11. Tests and Acceptance
|
|
|
|
Automated tests cover:
|
|
|
|
- representative material numbers such as `4300-CA2260-A300` without imposing
|
|
a fixed syntax;
|
|
- capture before selection or dialog invocation;
|
|
- multiple logical components, units, and parameter coordinate sets;
|
|
- case-insensitive trimmed name matching and ambiguous duplicates;
|
|
- old-only, new-only, hidden, and visible parameters;
|
|
- ordinary values remaining from the new library;
|
|
- each presentation field copied independently;
|
|
- field-level warning behavior and report contents;
|
|
- exact `Part Label -> Value` write/read-back;
|
|
- missing/empty/ambiguous fields and forced write failure causing Undo;
|
|
- persisted `Value` verification after save;
|
|
- exact Undo restoration of values and presentation; and
|
|
- real `cscript` execution through a fake object host without source-text-only
|
|
claims.
|
|
|
|
Live 7.9.5 acceptance uses disposable projects and records screenshots or
|
|
machine evidence for parameter positions, colors, sizes, orientation,
|
|
visibility, ordinary new-library values, exact `Value`, Undo, save, and
|
|
persisted reread. Until every required route and case passes, the package
|
|
remains evaluation-only.
|