# DxDesigner 7.9.5 Automatic Reference Designator Tool
|
|
|
|
Date: 2026-09-01
|
|
|
|
## 1. Purpose
|
|
|
|
Build the first module of a maintainable DxDesigner 7.9.5 productivity suite: automatic reference designator assignment with preview, validation, safe write-back, and recovery.
|
|
|
|
The tool replaces the legacy workflow that copies selected reference designators to Excel, generates values manually, and pastes them back. Excel is not part of the new annotation workflow.
|
|
|
|
## 2. Compatibility Baseline
|
|
|
|
DxDesigner/Expedition Enterprise 7.9.5 is the only supported schematic integration baseline for this phase.
|
|
|
|
The installation and import flow must remain compatible with the method demonstrated by the supplied legacy tool:
|
|
|
|
1. The user opens DxDesigner 7.9.5.
|
|
2. The user opens `Settings -> Run at Startup`.
|
|
3. The user adds one `MenuAdd.vbs` file to the Scripts list.
|
|
4. After DxDesigner restarts, one `Dx Productivity` menu appears on the Sheet Menu Bar.
|
|
|
|
The integration must not require a newer Xpedition add-in framework, a copied DLL from another release, COM re-registration, or a project-format upgrade.
|
|
|
|
`MenuAdd.vbs` uses only interfaces already demonstrated in the legacy package:
|
|
|
|
- `Scripting.GetEnvVariable`
|
|
- `CommandBars("Sheet Menu Bar").Controls.Add`
|
|
- menu control captions and `OnAction`
|
|
- the 7.9.5 internal scripting host
|
|
|
|
The installer sets a user-level `DXTOOLS_HOME` environment variable. `MenuAdd.vbs` resolves every tool path through `Scripting.GetEnvVariable("DXTOOLS_HOME")`; it contains no `D:\NET_CHECK` or other fixed installation path. DxDesigner must be restarted after installation so its script host sees the new environment value.
|
|
|
|
## 3. Compatibility Probe
|
|
|
|
The first implementation milestone is a read-only 7.9.5 probe imported through the exact startup-script flow above. It must not change a schematic.
|
|
|
|
The probe verifies:
|
|
|
|
- the imported script can add and remove its own menu entries without duplication;
|
|
- a menu item can enter the internal VBS bridge and launch the configured Python executable;
|
|
- `ActiveView.Query(VDM_COMP, VD_SELECTED)` returns selected components;
|
|
- `Application.DesignComponents` enumerates the full design;
|
|
- component reference designator, sheet number, X/Y position, attributes, full path, and stable identity are readable;
|
|
- the bridge can hold component object references while the Python process is open;
|
|
- UTF-8 snapshot and result files can be exchanged through the user-local run directory.
|
|
|
|
The release menu action uses the first 7.9.5-native route proven by the probe. The permitted routes, in order, are:
|
|
|
|
1. a named bridge procedure in the imported startup VBS;
|
|
2. the 7.9.5 `Run` script action;
|
|
3. the proven `Form` action with a minimal 7.9.5 EFM launcher.
|
|
|
|
No unverified route is shipped. If the first two routes are unavailable, the launcher EFM is created or adapted using the 7.9.5 form format; it is not copied from a newer release.
|
|
|
|
## 4. Architecture
|
|
|
|
```text
|
|
DxDesigner 7.9.5
|
|
-> imported MenuAdd.vbs
|
|
-> internal VBS bridge
|
|
-> UTF-8 snapshot + in-memory component map
|
|
-> Python/PySide6 application
|
|
-> validated bridge_id/new_refdes result
|
|
-> VBS write-back and full-design verification
|
|
```
|
|
|
|
### 4.1 VBS integration layer
|
|
|
|
The VBS layer owns every DxDesigner COM/API call. It reads the current design, launches Python, waits for the result, revalidates the snapshot, applies changes, verifies the design, and rolls back on failure.
|
|
|
|
Python does not attach directly to `ViewDraw.Application`. This avoids 32-bit versus 64-bit COM registration and licensing incompatibilities between DxDesigner 7.9.5 and modern Python.
|
|
|
|
### 4.2 Python domain layer
|
|
|
|
The Python domain layer is independent of DxDesigner. It parses snapshots, groups components, computes deterministic annotation plans, validates collisions, and produces an immutable change set.
|
|
|
|
This layer has no GUI imports and can be exhaustively unit tested with fixtures.
|
|
|
|
### 4.3 Python UI layer
|
|
|
|
The desktop UI uses PySide6 and a local style sheet. It implements the approved three-column workbench:
|
|
|
|
- suite navigation on the left;
|
|
- annotation rules in the center;
|
|
- live old-to-new preview on the right.
|
|
|
|
The source remains runnable with the installed Python 3.12 environment. A later packaging step may produce a standalone executable, but packaging does not change the VBS bridge protocol.
|
|
|
|
## 5. Bridge Protocol
|
|
|
|
Each run uses a unique directory:
|
|
|
|
```text
|
|
%LOCALAPPDATA%\DxProductivity\runs\<run_id>\
|
|
request.json
|
|
result.tsv
|
|
apply-status.json
|
|
```
|
|
|
|
VBS writes `request.json` as UTF-8 using a deterministic JSON escaping helper. Python writes an ordered `result.tsv` apply schedule with five constrained fields: `sequence`, `bridge_id`, `expected_refdes`, `new_refdes`, and `final_refdes`. Tabs and line breaks are illegal in every result field.
|
|
|
|
Each sequence number is unique and contiguous from 1. A bridge ID normally appears once. It may appear twice only when a validated reannotation cycle requires a temporary placeholder step followed by the final assignment. VBS verifies `expected_refdes` immediately before every step and verifies `final_refdes` after the complete schedule.
|
|
|
|
Each snapshot component contains:
|
|
|
|
- ephemeral `bridge_id` assigned by the current VBS run;
|
|
- stable UID when exposed by 7.9.5;
|
|
- hierarchical full path as an identity fallback;
|
|
- sheet number and current-view membership;
|
|
- X and Y schematic coordinates;
|
|
- current reference designator;
|
|
- symbol-level default reference designator or prefix when available;
|
|
- selection state;
|
|
- part number and Value for preview;
|
|
- lock or protection state when exposed by 7.9.5.
|
|
|
|
VBS retains an in-memory `bridge_id -> component object` map while Python is open. Result rows never rely on COM enumeration order.
|
|
|
|
Before write-back, VBS confirms that the active design, component identity, component count in scope, and original reference designators still match the snapshot. A mismatch invalidates the plan and requires a refresh.
|
|
|
|
## 6. Annotation Behavior
|
|
|
|
### 6.1 Scope
|
|
|
|
The UI supports three explicit scopes:
|
|
|
|
- selected components, which is the default;
|
|
- current sheet;
|
|
- full design.
|
|
|
|
If the selected scope is empty, Apply remains disabled. The tool does not silently fall back to another scope.
|
|
|
|
### 6.2 Processing mode
|
|
|
|
The default mode fills only unannotated components:
|
|
|
|
- blank reference designators;
|
|
- placeholders matching a leading alphabetic prefix followed by one or more question marks, such as `R?`, `C??`, or `TP?`.
|
|
|
|
Existing formal reference designators are preserved. A separate, explicit mode reannotates every eligible component in scope.
|
|
|
|
### 6.3 Prefix resolution
|
|
|
|
Prefix resolution is deterministic:
|
|
|
|
1. use the alphabetic prefix in the current placeholder;
|
|
2. otherwise use the symbol-level default reference designator/prefix exposed by 7.9.5;
|
|
3. otherwise require an explicit prefix in the preview table.
|
|
|
|
An unresolved prefix is a blocking validation error. Prefix comparison is case-insensitive and output is normalized to uppercase.
|
|
|
|
### 6.4 Multi-unit components
|
|
|
|
All symbols that represent the same logical component are grouped by stable component identity. They receive one base reference designator. Symbol units or gates do not consume additional sequence numbers.
|
|
|
|
If 7.9.5 does not expose a stable UID, the compatibility adapter derives a stable grouping key from the hierarchical component path and validated component metadata. Ambiguous groups are blocked rather than guessed.
|
|
|
|
### 6.5 Sorting
|
|
|
|
The default order is:
|
|
|
|
1. numeric sheet number ascending;
|
|
2. schematic Y coordinate from top to bottom;
|
|
3. X coordinate from left to right within the same visual row;
|
|
4. stable identity as the final deterministic tie-breaker.
|
|
|
|
Because schematic Y-axis direction is API-dependent, the compatibility adapter normalizes coordinates so larger visual height always sorts first. Components are grouped into visual rows using a default 5 mm tolerance. The user can change the tolerance.
|
|
|
|
Alternative orders are available for left-to-right column scanning and reverse directions.
|
|
|
|
### 6.6 Numbering modes
|
|
|
|
Continuous mode is the default. Each prefix owns an independent sequence beginning at 1 unless the user changes the start value. Numbers already used anywhere outside the target set are skipped.
|
|
|
|
Page mode uses:
|
|
|
|
```text
|
|
number = numeric_sheet_number * page_step + page_start
|
|
```
|
|
|
|
The defaults are `page_step = 100` and `page_start = 1`, so sheet 3 starts at 301. Each prefix has an independent page sequence. Non-numeric sheet identifiers require an explicit numeric mapping before Apply.
|
|
|
|
### 6.7 Collision rules
|
|
|
|
Validation is case-insensitive and covers:
|
|
|
|
- duplicates inside the proposed change set;
|
|
- collisions with components outside the target set;
|
|
- illegal or empty prefixes;
|
|
- invalid numeric ranges;
|
|
- duplicate existing formal reference designators in the source design;
|
|
- multiple proposed values for one logical component.
|
|
|
|
Blocking issues disable Apply. Warnings remain selectable and can locate the affected schematic component.
|
|
|
|
## 7. Safe Apply and Recovery
|
|
|
|
Every Apply operation follows this sequence:
|
|
|
|
1. revalidate the snapshot against the active design;
|
|
2. run all collision and format checks again;
|
|
3. write a timestamped backup mapping under `%LOCALAPPDATA%\DxProductivity\backups`;
|
|
4. apply changes using the in-memory component map;
|
|
5. re-enumerate the full design and verify every expected reference designator;
|
|
6. write a machine-readable apply status and append an operation-history entry.
|
|
|
|
Fill-only plans normally write directly because they cannot swap existing formal identifiers.
|
|
|
|
Full reannotation plans are ordered as a dependency graph. Acyclic moves are applied first. Cycles use the component prefix placeholder, such as `R?`, as a temporary value, then complete the cycle. This uses a placeholder format already accepted by DxDesigner 7.9.5 instead of inventing a new temporary reference-designator syntax.
|
|
|
|
If any assignment or verification fails, VBS restores every component from the backup mapping and verifies the restoration. A rollback failure is reported prominently with the backup path and the exact remaining mismatch.
|
|
|
|
The operation-history view exposes Restore Last Annotation. Restore performs the same preflight, backup, apply, and verification sequence; it is not a blind file replay.
|
|
|
|
## 8. User Interface and Visual Acceptance
|
|
|
|
The approved mockup is the visual baseline. The release implementation follows these measurable requirements derived from Apple Human Interface Guidelines while remaining a Windows desktop application:
|
|
|
|
- 13 pt default content text and no essential text below 10 pt;
|
|
- approximately 28 by 28 pt default desktop controls and no interactive target below 20 by 20 pt;
|
|
- 16 px simplified line icons with consistent weight and optical alignment;
|
|
- tooltips and accessible names for icon-only controls;
|
|
- one semantic use per status color;
|
|
- text contrast of at least 4.5:1 for normal text;
|
|
- icons or text in addition to color for every status;
|
|
- light, dark, and increased-contrast-compatible palettes;
|
|
- complete keyboard navigation with visible focus;
|
|
- no clipping or overlap at 100%, 125%, and 150% Windows display scaling;
|
|
- a resizable window with a minimum supported content area of 1100 by 700 logical pixels;
|
|
- no required command placed only at the bottom edge of the window;
|
|
- no automatic, blinking, bouncing, or decorative motion.
|
|
|
|
Interface icons use a cross-platform icon set with Apple-like semantic consistency. Apple SF Symbols are a design reference only and are not redistributed in the Windows application.
|
|
|
|
Official design references:
|
|
|
|
- [Designing for macOS](https://developer.apple.com/design/human-interface-guidelines/designing-for-macos)
|
|
- [Layout](https://developer.apple.com/design/human-interface-guidelines/layout)
|
|
- [Typography](https://developer.apple.com/design/human-interface-guidelines/typography)
|
|
- [Color](https://developer.apple.com/design/human-interface-guidelines/color)
|
|
- [Accessibility](https://developer.apple.com/design/human-interface-guidelines/accessibility)
|
|
- [Icons](https://developer.apple.com/design/human-interface-guidelines/icons)
|
|
|
|
## 9. Error Handling
|
|
|
|
Errors are divided into three levels:
|
|
|
|
- blocking: Apply is disabled, for example duplicate output or missing prefix;
|
|
- warning: the plan remains applicable after review, for example a nonstandard existing designator outside scope;
|
|
- informational: no action required, for example a locked component preserved by policy.
|
|
|
|
The UI shows an icon, short message, affected component count, and location action. Technical details and bridge logs are available in a diagnostics view and retained per run. Normal users do not need to inspect raw JSON, TSV, COM error codes, or Python tracebacks.
|
|
|
|
If Python is missing or cannot start, the VBS bridge shows a concise message with the configured executable path and exits without changing the design.
|
|
|
|
## 10. Testing Strategy
|
|
|
|
### 10.1 Automated domain tests
|
|
|
|
Tests cover:
|
|
|
|
- placeholder recognition and prefix normalization;
|
|
- continuous and page numbering;
|
|
- occupied-number skipping;
|
|
- row tolerance and every sort direction;
|
|
- numeric and non-numeric sheet identifiers;
|
|
- multi-unit grouping;
|
|
- duplicate and collision detection;
|
|
- deterministic output for equal coordinates;
|
|
- reannotation dependency graphs and cycles;
|
|
- backup and restore plan generation.
|
|
|
|
### 10.2 Bridge contract tests
|
|
|
|
Pure VBS helpers are tested with `cscript` where possible. Tests cover UTF-8, JSON escaping, result parsing, invalid rows, duplicate or noncontiguous sequence numbers, unknown bridge IDs, illegal repeated bridge steps, stale snapshots, and simulated assignment failures.
|
|
|
|
Python contract tests use captured 7.9.5-compatible fixtures and never require a live DxDesigner instance.
|
|
|
|
### 10.3 UI tests
|
|
|
|
Qt tests cover default selections, scope changes, preview filtering, blocking-error behavior, keyboard tab order, light/dark themes, and Apply confirmation for full reannotation.
|
|
|
|
Screenshots are checked at representative 1100 by 700 and 1440 by 900 window sizes under 100%, 125%, and 150% scaling. Text, controls, and tables must not overlap or clip.
|
|
|
|
### 10.4 Live 7.9.5 acceptance
|
|
|
|
The user runs the compatibility probe and a sample-project acceptance checklist on the target DxDesigner 7.9.5 installation. Live acceptance covers startup-script import, menu creation, selected/current/full scopes, coordinate order, write-back, duplicate prevention, rollback, restoration, Chinese installation paths, and paths containing spaces.
|
|
|
|
No release is marked 7.9.5-compatible solely from mocked COM tests.
|
|
|
|
## 11. Deliverables for Phase One
|
|
|
|
- 7.9.5 compatibility probe;
|
|
- installer and uninstall instructions using startup-script import;
|
|
- `MenuAdd.vbs` and the verified 7.9.5 bridge adapter;
|
|
- Python source and dependency metadata;
|
|
- automatic reference designator GUI;
|
|
- annotation domain tests and bridge contract tests;
|
|
- live 7.9.5 acceptance checklist;
|
|
- user guide for installation, annotation, preview, Apply, and Restore.
|
|
|
|
## 12. Non-Goals
|
|
|
|
This phase does not implement Value/Value1/Part Number editing, attribute visibility, design audits, network navigation, BOM generation, BOM-to-schematic navigation, or Expedition PCB assembly text placement. Those modules reuse the verified bridge and shared application shell in later phase-specific designs.
|
|
|
|
This phase does not import code or binaries from newer Xpedition releases and does not modify the DxDesigner project format.
|